MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.brs.2021.09.014

Медицинская библиотека · Brain stimulation · 2021

Effects of modifying the electrode placement and pulse width on cognitive side effects with unilateral ECT: A pilot randomised controlled study with computational modelling.

Martin Donel M, Bakir Azam Ahmad, Lin Feng, Francis-Taylor Rohan, Alduraywish Abdulrahman, Bai Siwei, Hadzi-Pavlovic Dusan, Dokos Socrates, Loo Colleen K

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The electrode placement and pulse width for electroconvulsive therapy (ECT) are important treatment parameters associated with ECT related retrograde memory side-effects. Modification of these parameters with right unilateral (RUL) ECT may have utility for further reducing these side-effects.

OBJECTIVE

This study explored use of the frontoparietal (FP) placement for reducing retrograde memory side effects with ECT. We hypothesised that superior retrograde memory outcomes would occur with FP compared to temporoparietal (TP) placement and with ultrabrief (UB: 0.3 ms) compared to brief pulse (BP: 1.0 ms) width ECT.

METHODS

In this randomised cross-over, double-blinded study, participants received a single treatment of BP TP, BP FP, UB TP and UB FP ECT. Neuropsychological testing was conducted prior to and immediately following each treatment. Computational modelling was conducted to explore associations between E-fields in regions-of-interest associated with memory.

RESULTS

Nine participants completed the study. The FP placement was not superior to TP for retrograde memory outcomes. For both electrode placements UB pulse width was associated with significantly better visual retrograde memory compared to BP (p < .05). With TP ECT, higher E-fields in regions-of-interest were significantly associated with greater visual retrograde memory side-effects (hippocampi: r = -0.77, p = .04; inferior frontal gyri: r = -0.92, p < .01; middle frontal gyri: r = -0.84, p = .02).

CONCLUSIONS

Modification of pulse-width had greater effects than electrode placement for reducing retrograde memory side-effects with RUL ECT. Preliminary findings suggested that higher E-fields may be associated with greater cognitive side-effects with ECT.

Для цитирования: Martin Donel M, Bakir Azam Ahmad, Lin Feng, Francis-Taylor Rohan, Alduraywish Abdulrahman, Bai Siwei, Hadzi-Pavlovic Dusan, Dokos Socrates, Loo Colleen K. Effects of modifying the electrode placement and pulse width on cognitive side effects with unilateral ECT: A pilot randomised controlled study with computational modelling.. Brain stimulation. 2021. DOI: 10.1016/j.brs.2021.09.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.