m+Medelevator.RU
← Поиск публикаций
Clinical rehabilitation · 2004

Development of the Brunel Balance Assessment: a new measure of balance disability post stroke.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tyson Sarah F, DeSouza Lorraine H

Аннотация

OBJECTIVE: To report the psychometric properties of the Brunel Balance Assessment (BBA), a new test of balance disability post stroke.

DESIGN: Data from 92 subjects were collected and cohorts used to test hierarchical scaling, reliability and validity. Data from 80 people were used to test the hierarchical scaling using an inter-item correlation for redundancy, coefficient of reproducibility (CR) and scalability (CS) for the hierarchy and Cronbach's alpha coefficient for the internal consistency. Thirty-seven people participated in the reliability testing. Test-retest and inter-tester reliability were tested using the kappa coefficient. The testing was repeated on consecutive days to assess test-retest reliability and was scored simultaneously by two physiotherapists for inter-tester reliability. Fifty-five people participated in validity testing. The BBA was compared with the sitting Motor Assessment Scale (MAS), Berg Balance Test (Berg), Rivermead Mobility Index (RMI) using Spearman's rho.

SETTING: Physiotherapy stroke services of six UK NHS trusts.

PARTICIPANTS: Hemiplegic stroke patients were recruited from physiotherapy services and the BBA used to assess their balance.

RESULTS: The order of the items was revised and the original 14-point scale reduced to 12 points in the scale development. The revised scale formed a hierarchical scale. Inter-item correlations were < 0.9, coefficients of reproducibility and scalability were 0.99 and 0.69 respectively and Cronbach's alpha was 0.92. Reliability was high (100% agreement) for both aspects of reliability. Correlations with other balance measures were significant (0.83-0.97, p < 0.01) indicating validity as measure of balance disability.

CONCLUSION: The BBA is a reliable, valid, hierarchical measure of balance disability post stroke that is suitable for use in the clinical setting.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты