MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/cre2.70222

Медицинская библиотека · Clinical and experimental dental research · 2025

The Effects of Laboratory Contamination of Implant Abutment Screw and Connection on Reverse Torque Value - An In Vitro Study.

Bahrami Maleki Hamed, Bazooband Mona, Amini Parviz

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

This in vitro experimental study aimed to evaluate the effects of laboratory contamination of implant abutment screws and connection surfaces on reverse torque values (RTVs), as an indicator of screw preload loss.

MATERIAL AND

METHODS

Forty-five Dentis One Q implants and 45 CCM UCLA abutments were randomly assigned into three groups (n = 15 per group). Group 1 (control) involved uncontaminated abutments and screws with no restorations. Group 2 (screw contamination) used new abutments attached with screws contaminated by laboratory materials (porcelain powder, metal debris, and polishing paste). Group 3 (connection contamination) included screw-retained restorations fabricated under contaminated conditions and attached using new screws. All samples were subjected to standardized torque (250 N·cm), thermocycling (1500 cycles between 5°C and 55°C), and subsequent RTV measurement. One-way ANOVA and Tukey's post hoc tests were used for statistical analysis (α = 0.05).

RESULTS

Mean RTVs (SD) were 218 (0.15) N·cm (control), 181 (0.14) N·cm (screw contamination), and 207 (0.11) N·cm (connection contamination). RTVs in the screw contamination group were significantly lower than both the control (p < 0.001) and connection contamination groups (p < 0.001). The difference between the control and connection contamination groups was not statistically significant (p = 0.08).

CONCLUSIONS

Laboratory contamination of implant components can significantly reduce reverse torque values, particularly in cases of screw contamination, indicating an increased risk of screw loosening. Contamination control during prosthetic procedures is essential to maintaining implant stability.

Для цитирования: Bahrami Maleki Hamed, Bazooband Mona, Amini Parviz. The Effects of Laboratory Contamination of Implant Abutment Screw and Connection on Reverse Torque Value - An In Vitro Study.. Clinical and experimental dental research. 2025. DOI: 10.1002/cre2.70222.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.