MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijo.ijo_2525_24

Медицинская библиотека · Indian journal of ophthalmology · 2025

Diagnostic accuracy of Bruch's membrane opening minimum rim width for detecting glaucoma in Indian myopic eyes.

Kader Mohideen Abdul, Thangavel Jeyapriya, Pillai Madhavi Ramanatha, Gupta Shivam, Uduman Mohammed Sithiq, Ramakrishnan Rengappa

СтатьяПеревод в очереди

Аннотация

PURPOSE: To analyze Bruch's membrane opening minimum rim width (BMO-MRW) for detecting glaucoma in patients with myopia < -6D and assessment of peripapillary retinal nerve fiber layer thickness (pRNFLT).

METHODS

One eye was randomly selected from each of the 90 subjects (A-30 normal controls, B-30 with glaucoma suspect, and C-30 with primary open-angle glaucoma [POAG]). All patients underwent baseline ophthalmic evaluation. BMO- MRW and pRNFLT data were obtained using spectral-domain optical coherence tomography (Spectralis, Heidelberg Engineering GmbH, Heidelberg, Germany). The area under the receiver operating characteristic curves (AUC) for global and sectoral thickness parameters was calculated.

RESULTS

Sectoral analysis of BMO-MRW for the discrimination of early glaucoma in all myopic subjects showed significantly better diagnostic performance than pRNFLT in temporal (0.85 (0.77 to 0.94) P = 0.014), temporal superior (TS) (0.90 (0.83 to 0.98) P = 0.005), and nasal inferior quadrants (0.92 (0.86 to 0.97) P = 0.022) with 95% CI. When discriminating early glaucoma from the suspect, overall the diagnostic performance of BMO-MRW was higher than that of pRNFLT, with significant differences in the temperosuperior quadrant (0.85 (0.74 to 0.95) 95% CI, P = 0.047).

CONCLUSION

BMO-MRW had better diagnostic performance than RNFL thickness and is a useful parameter for detecting glaucoma in myopic eyes (≤-6D) with POAG.

Для цитирования: Kader Mohideen Abdul, Thangavel Jeyapriya, Pillai Madhavi Ramanatha, Gupta Shivam, Uduman Mohammed Sithiq, Ramakrishnan Rengappa. Diagnostic accuracy of Bruch's membrane opening minimum rim width for detecting glaucoma in Indian myopic eyes.. Indian journal of ophthalmology. 2025. DOI: 10.4103/ijo.ijo_2525_24.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.