Journal of hepato-biliary-pancreatic sciences · 2022
A novel bipolar electrocautery-enhanced delivery system with a lumen-apposing metal stent for EUS-guided drainage: A porcine study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Jo Seok Jung, Moon Jong Ho, Lee Yun Nah, Park Jae Keun, Lee Tae Hoon, Park Sang-Heum, Park Se Ik, Jeong Seok, Lee Don Haeng
Аннотация
BACKGROUND: An electrocautery-enhanced delivery system with a lumen-apposing metal stent (LAMS) is available for one-step endoscopic ultrasound-guided transmural drainage (EUS-TD). Bipolar electrosurgery has several potential clinical advantages, including reduced collateral thermal damage, enhanced hemostasis, and no requirement for a return electrode plate. In this study, we compared the technical feasibility and safety of a newly developed bipolar electrocautery-enhanced delivery system with a conventional delivery system for EUS-TD using a LAMS in a porcine model.
METHOD: Ten days before the study, 12 mini pigs underwent common bile duct ligation for EUS-guided gallbladder drainage. Transenteric puncture was performed, followed by placement of a guidewire. In six pigs, a bipolar electrocautery-enhanced delivery system with LAMS (Hot SPAXUS) was inserted over the guidewire and advanced into the gallbladder, without prior dilation of the tract, by applying a bipolar cut current. In the remaining six pigs, a conventional delivery system with LAMS (Cold SPAXUS) was inserted after tract dilatation using a cystotome. The stent was removed after 4 weeks.
RESULTS: In all pigs, the stent was successfully inserted and deployed in the gallbladder without adverse events. The mean procedure time of EUS-TD was significantly lower in the Hot SPAXUS group than that of the Cold SPAXUS group (mean ± standard deviation: 188.7 ± 5.2 vs 449.5 ± 97.5 s, P = .0019). Stent migration was not observed, and all stents were removed successfully.
CONCLUSIONS: Endoscopic ultrasound-guided transmural drainage using a bipolar electrocautery-enhanced LAMS is feasible for reducing the procedure time while maintaining the high success rate and safety of conventional LAMS.
METHOD: Ten days before the study, 12 mini pigs underwent common bile duct ligation for EUS-guided gallbladder drainage. Transenteric puncture was performed, followed by placement of a guidewire. In six pigs, a bipolar electrocautery-enhanced delivery system with LAMS (Hot SPAXUS) was inserted over the guidewire and advanced into the gallbladder, without prior dilation of the tract, by applying a bipolar cut current. In the remaining six pigs, a conventional delivery system with LAMS (Cold SPAXUS) was inserted after tract dilatation using a cystotome. The stent was removed after 4 weeks.
RESULTS: In all pigs, the stent was successfully inserted and deployed in the gallbladder without adverse events. The mean procedure time of EUS-TD was significantly lower in the Hot SPAXUS group than that of the Cold SPAXUS group (mean ± standard deviation: 188.7 ± 5.2 vs 449.5 ± 97.5 s, P = .0019). Stent migration was not observed, and all stents were removed successfully.
CONCLUSIONS: Endoscopic ultrasound-guided transmural drainage using a bipolar electrocautery-enhanced LAMS is feasible for reducing the procedure time while maintaining the high success rate and safety of conventional LAMS.