m+Medelevator.RU
← Поиск публикаций
European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022

Arthroscopically assisted single tunnel reconstruction for acute high-grade acromioclavicular joint dislocation with an additional acromioclavicular joint cerclage.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jensen Gunnar, Dey Hazra Rony-Orijit, Al-Ibadi Mireille, Salmoukas Katharina, Katthagen Jan Christoph, Lill Helmut, Ellwein Alexander

Аннотация

PURPOSE: Purpose of this study was to demonstrate that a single tunnel reconstruction of high-grade acromioclavicular (AC) joint instabilities with implants of the second generation is sufficient for stabilisation, especially in combination with an AC cerclage.

METHODS: Patients with an acute AC-joint dislocation type Rockwood III-B and V were included. Besides clinical follow-up examination, radiographs were analysed. The functional outcome measures were Constant Score (CS), Taft score (TS), ACJI score and patient's satisfaction. Horizontal instability was evaluated by clinical examination and radiological with an Alexander view.

RESULTS: Thirty-five patients with a mean follow-up of 29 months were included. Ninety-seven per cent were satisfied with their result, with an average Subjective Shoulder Value of 90%. The CS averaged at 90 ± 10 points, TS at 11 ± 1 points and ACJI at 78 ± 18 points. Radiologically, 3 of 29 patients (10%) showed a persisting horizontal instability. The coracoclavicular (CC) distance improved from 22 preoperative to 10 mm postoperative, which was comparable to the contralateral side (10 mm, p = 0.103). At follow-up the CC distance increased to 13 mm (p = 0.0001).

CONCLUSION: AC-joint stabilisation with a single tunnel reconstruction using a second-generation implant results in good to excellent clinical results with high patient satisfaction. The additional AC augmentation improves stability in horizontal instable AC-joints and is recommended in all high-grade AC joint stabilisations. Nonetheless, reduction was slightly lost over time due to an elongation or suture failure of the coraco-clavicular fixation.

LEVEL OF EVIDENCE: IV.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты