DOI 10.1111/j.1540-8167.2011.02085.x

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2011

Electrocardiographic versus echocardiographic optimization of the interventricular pacing delay in patients undergoing cardiac resynchronization therapy.

Tamborero David, Vidal Barbara, Tolosana Jose Maria, Sitges Marta, Berruezo Antonio, Silva Etelvino, Castel Mángeles, Matas Mariona, Arbelo Elena, Rios Jose, Villacastín Julián, Brugada Josep, Mont Lluís

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

Echocardiographic optimization of the VV interval may improve CRT response, but it is time-consuming and not routinely performed. The aim of this study was to compare the response to cardiac resynchronization therapy (CRT) when the interventricular pacing (VV) interval was optimized by tissue Doppler imaging (TDI) to CRT response when it was optimized following QRS width criteria.

METHODS AND

RESULTS

The study included 156 consecutive CRT patients with severe heart failure and left bundle-branch block configuration. Atrioventricular interval was selected according to a pulsed Doppler assessment, and VV optimization was randomly assigned to echocardiography (ECHO group, n = 78) or electrocardiography (ECG group, n = 78). Optimal VV was defined for the ECHO group as producing the best LV intraventricular synchrony according to TDI displacement curves and for the ECG group as resulting in the narrowest QRS measured from the earliest deflection. At 6-month follow-up, percentage of echocardiographic responders (defined as neither death nor heart transplantation and a LV end-systolic volume reduction >10%) was higher in the ECG optimized group (50.0% vs 67.9%; P = 0.023), whereas clinical response (defined as neither death nor heart transplantation and >10% improvement in the 6-minute walking test) was similar in both groups (71.8% vs 73.1%; P = 0.858).

CONCLUSIONS

VV optimization based on QRS width obtained a higher percentage of responders in terms of LV reverse remodeling compared to the TDI method.

Для цитирования: Tamborero David, Vidal Barbara, Tolosana Jose Maria, Sitges Marta, Berruezo Antonio, Silva Etelvino, Castel Mángeles, Matas Mariona, Arbelo Elena, Rios Jose, Villacastín Julián, Brugada Josep, Mont Lluís. Electrocardiographic versus echocardiographic optimization of the interventricular pacing delay in patients undergoing cardiac resynchronization therapy.. Journal of cardiovascular electrophysiology. 2011. DOI: 10.1111/j.1540-8167.2011.02085.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.