DOI 10.1111/j.1540-8167.2011.02052.x

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2011

Positioning of left ventricular pacing lead guided by intracardiac echocardiography with vector velocity imaging during cardiac resynchronization therapy procedure.

Bai Rong, Di Biase Luigi, Mohanty Prasant, Hesselson Aaron B, De Ruvo Ermenegildo, Gallagher Peter L, Elayi Claude S, Mohanty Sanghamitra, Sanchez Javier E, Burkhardt J David, Horton Rodney, Gallinghouse G Joseph, Bailey Shane M, Zagrodzky Jason D, Canby Robert, Minati Monia, Price Larry D, Hutchins C Lynn, Muir Melody A, Calo' Leonardo, Natale Andrea, Tomassoni Gery F

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

Intraoperative modality for "real-time" left ventricular (LV) dyssynchrony quantification and optimal resynchronization is not established. This study determined the feasibility, safety, and efficacy of intracardiac echocardiography (ICE), coupled with vector velocity imaging (VVI), to evaluate LV dyssynchrony and to guide LV lead placement at the time of cardiac resynchronization therapy (CRT) implant.

METHODS

One hundred and four consecutive heart failure patients undergoing ICE-guided (Group 1, N = 50) or conventional (Group 2, N = 54) CRT implant were included in the study. For Group 1 patients, LV dyssynchrony and resynchronization were evaluated by VVI including visual algorithms and the maximum differences in time-to-peak (MD-TTP) radial strain. Based on the findings, the final LV lead site was determined and optimal resynchronization was achieved. CRT responders were defined using standard criteria 6 months after implantation.

RESULTS

Both groups underwent CRT implant with no complications. In Group 1, intraprocedural optimal resynchronization by VVI including visual algorithms and MD-TTP was a predictor discriminating CRT response with a sensitivity of 95% and specificity of 89%. Use of ICE/VVI increased number of and predicted CRT responders (82% in Group 1 vs 63% in Group 2; OR = 2.68, 95% CI 1.08-6.65, P = 0.03).

CONCLUSION

ICE can be safely performed during CRT implantation. "Real-time" VVI appears to be helpful in determining the final LV lead position and pacing mode that allow better intraprocedural resynchronization. VVI-optimized acute resynchronization predicts CRT response and this approach is associated with higher number of CRT responders.

Для цитирования: Bai Rong, Di Biase Luigi, Mohanty Prasant, Hesselson Aaron B, De Ruvo Ermenegildo, Gallagher Peter L, Elayi Claude S, Mohanty Sanghamitra, Sanchez Javier E, Burkhardt J David, Horton Rodney, Gallinghouse G Joseph, Bailey Shane M, Zagrodzky Jason D, Canby Robert, Minati Monia, Price Larry D, Hutchins C Lynn, Muir Melody A, Calo' Leonardo, Natale Andrea, Tomassoni Gery F. Positioning of left ventricular pacing lead guided by intracardiac echocardiography with vector velocity imaging during cardiac resynchronization therapy procedure.. Journal of cardiovascular electrophysiology. 2011. DOI: 10.1111/j.1540-8167.2011.02052.x.