m+Medelevator.RU
← Поиск публикаций
IEEE transactions on bio-medical engineering · 2026

Towards Wearable High-Density MEG: A Compact, Low-Power, and Scalable OPM-MEG System with Automated Control.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

He Kaiyan, Yang Rui, Li Congcong, Cai Yuyao, Cheng Hao, Jin Zeyu, Li Dongxu, Zheng Fufu, Zou Pingchuan, Lyu Bingjiang, Gao Jia-Hong

Аннотация

OBJECTIVE/BACKGROUND: Optically pumped magnetometer-based magnetoencephalography (OPM-MEG) is advancing toward wearable and high-density sensor configurations, posing significant engineering challenges in miniaturization, thermal management, and scalable integration. Here, we present a high-performance wearable OPM-MEG system that addresses these challenges.

METHODS: The system was developed through a system-level co-design of the sensor head and electronic control units (ECUs) with a fully automated control workflow. To reduce thermal dissipation and lower scalp temperature, we implemented a thermally optimized suspended vapor-cell module.

RESULTS: This design achieves a miniaturized sensor head (12 × 16.5 × 22.5 mm3) and ECU footprint (34 × 28 mm2), with a total per-sensor power consumption of 3.5 W (0.7 W allocated to the sensor head). Crucially, the sensor maintains high sensitivity required for detecting ultraweak brain magnetic fields, exhibiting single-axis sensitivity < 7 fT/$\sqrt$ Hz and dual-axis sensitivity < 10 fT/$\sqrt$ Hz, with a bandwidth of 130 Hz. Inter-sensor crosstalk and intra-sensor cross-axis projection error (CAPE) are suppressed to lower than 2%, addressing the critical challenge of signal interference in high-density sensor arrays. Phantom experiments demonstrate accurate source localization with a mean error of  1 mm, while human recordings provide further validation of stable and high-fidelity performance in wearable OPM-MEG settings.

CONCLUSION: Collectively, this work establishes a scalable, instrument-level framework for the design, automated operation, and quantitative end-to-end evaluation of high-density wearable OPM-MEG systems.

SIGNIFICANCE: This work provides a scalable foundation for high-density wearable OPM-MEG, enabling mobile brain measurements for brain-computer interfaces, cognitive neuroscience, and future translational clinical neuroimaging applications.