MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1536/ihj.48.11

Медицинская библиотека · International heart journal · 2007

Angiographic and clinical outcome following sirolimus-eluting stent (Cypher) implantation. A single center experience.

Ozcan Turkay, Cin V Gokhan, Yurtdas Mustafa, Akcay Burak, Seyis Sabri, Acele Armagan, Cicek Dilek, Camsari Ahmet, Akkus Necdet, Doven Oben

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To investigate the late outcomes of sirolimus-eluting stent implantation in patients with coronary artery disease.

BACKGROUND

Drug-eluting stents reduce intimal hyperplasia, which is the main cause of in-stent restenosis. Sirolimus-eluting stents significantly reduce clinical and angiographic restenosis and improve event-free survival.

METHODS

The study population consisted of 207 patients (273 stents) who had undergone coronary Cypher stent implantation. Patients were eligible for enrollment if there was symptomatic coronary artery disease or positive exercise testing, and angiographic evidence of single or multivessel disease with a target lesion stenosis of > or = 70% in a > or = 2.25 mm vessel. Follow-up coronary angiography was performed 18 months after stent deployment. Patients were followed-up for a mean of 24.7 +/- 7.4 months.

RESULTS

All patients survived after stent implantation, but 5 (2.4%) patients experienced acute ST elevation myocardial infarction and 4 (1.9%) patients developed non-Q wave myocardial infarction following angioplasty. Recurrent angina pectoris was observed in 16 (7.7%) patients (11 stable angina pectoris and 5 unstable angina pectoris). Angiographic evidence of restenosis was observed in these 20 (9.66%) patients. The 5 other patients had noncritical angiographic restenosis. Eleven (5.3%) patients underwent angioplasty because of restenosis, and coronary artery bypass grafting was conducted in the other 9 (4.3%) patients.

CONCLUSION

The results of the present study indicate that Cypher stents could be implanted with a very high success rate and have encouraging long-term angiographic and clinical results.

Для цитирования: Ozcan Turkay, Cin V Gokhan, Yurtdas Mustafa, Akcay Burak, Seyis Sabri, Acele Armagan, Cicek Dilek, Camsari Ahmet, Akkus Necdet, Doven Oben. Angiographic and clinical outcome following sirolimus-eluting stent (Cypher) implantation. A single center experience.. International heart journal. 2007. DOI: 10.1536/ihj.48.11.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.