MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2009.01.021

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2009

Incorporating cone-beam CT into the treatment planning for yttrium-90 radioembolization.

Louie John D, Kothary Nishita, Kuo William T, Hwang Gloria L, Hofmann Lawrence V, Goris Michael L, Iagaru Andrei H, Sze Daniel Y

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To prepare for yttrium-90 ((90)Y) microsphere radioembolization therapy, digital subtraction angiography (DSA) and technetium- 99m-labeled macroaggregated albumin ((99m)Tc MAA) scintigraphy are used for treatment planning and detection of potential nontarget embolization. The present study was performed to determine if cone-beam computed tomography (CBCT) affects treatment planning as an adjunct to these conventional imaging modalities.

MATERIALS AND

METHODS

From March 2007 to August 2008, 42 consecutive patients (21 men, 21 women; mean age, 59 years; range, 21-75 y) who underwent radioembolization were evaluated by CBCT in addition to DSA and (99m)Tc MAA scintigraphy during treatment planning, and their records were retrospectively reviewed. The contrast-enhanced territories shown by CBCT with selective intraarterial contrast agent administration were used to predict intrahepatic and possible extrahepatic distribution of microspheres.

RESULTS

In 22 of 42 cases (52%), extrahepatic enhancement or incomplete tumor perfusion seen on CBCT affected the treatment plan. In 14 patients (33%), the findings were evident exclusively on CBCT and not detected by DSA. When comparing CBCT versus (99m)Tc MAA scintigraphy, CBCT showed eight cases of extrahepatic enhancement (19%) that were not evident on (99m)Tc MAA imaging. CBCT findings directed the additional embolization of vessels or repositioning of the catheter for better contrast agent and microsphere distribution. One case of gastric ulcer from nontarget embolization caused by reader error was observed.

CONCLUSIONS

CBCT can provide additional information about tumor and tissue perfusion not currently detectable by DSA or (99m)Tc MAA imaging, which should optimize (90)Y microsphere delivery and reduce nontarget embolization.

Для цитирования: Louie John D, Kothary Nishita, Kuo William T, Hwang Gloria L, Hofmann Lawrence V, Goris Michael L, Iagaru Andrei H, Sze Daniel Y. Incorporating cone-beam CT into the treatment planning for yttrium-90 radioembolization.. Journal of vascular and interventional radiology : JVIR. 2009. DOI: 10.1016/j.jvir.2009.01.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.