DOI 10.1093/ehjci/jex173

Медицинская библиотека · European heart journal. Cardiovascular Imaging · 2018

Improved mitral valve coaptation and reduced mitral valve annular size after percutaneous mitral valve repair (PMVR) using the MitraClip system.

Patzelt Johannes, Zhang Yingying, Magunia Harry, Ulrich Miriam, Jorbenadze Rezo, Droppa Michal, Zhang Wenzhong, Lausberg Henning, Walker Tobias, Rosenberger Peter, Seizer Peter, Gawaz Meinrad, Langer Harald F

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: Improved mitral valve leaflet coaptation with consecutive reduction of mitral regurgitation (MR) is a central goal of percutaneous mitral valve repair (PMVR) with the MitraClip® system. As influences of PMVR on mitral valve geometry have been suggested before, we examined the effect of the procedure on mitral annular size in relation to procedural outcome.

METHODS AND

RESULTS

Geometry of the mitral valve annulus was evaluated in 183 patients undergoing PMVR using echocardiography before and after the procedure and at follow-up. Mitral valve annular anterior-posterior (ap) diameter decreased from 34.0 ± 4.3 to 31.3 ± 4.9 mm (P < 0.001), and medio-lateral (ml) diameter from 33.2 ± 4.8 to 32.4 ± 4.9 mm (P < 0.001). Accordingly, we observed an increase in MV leaflet coaptation after PMVR. The reduction of mitral valve ap diameter showed a significant inverse correlation with residual MR. Importantly, the reduction of mitral valve ap diameter persisted at follow-up (31.3 ± 4.9 mm post PMVR, 28.4 ± 5.3 mm at follow-up).

CONCLUSION

This study demonstrates mechanical approximation of both mitral valve annulus edges with improved mitral valve annular coaptation by PMVR using the MitraClip® system, which correlates with residual MR in patients with MR.

Для цитирования: Patzelt Johannes, Zhang Yingying, Magunia Harry, Ulrich Miriam, Jorbenadze Rezo, Droppa Michal, Zhang Wenzhong, Lausberg Henning, Walker Tobias, Rosenberger Peter, Seizer Peter, Gawaz Meinrad, Langer Harald F. Improved mitral valve coaptation and reduced mitral valve annular size after percutaneous mitral valve repair (PMVR) using the MitraClip system.. European heart journal. Cardiovascular Imaging. 2018. DOI: 10.1093/ehjci/jex173.