MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/13645706.2014.951656

Медицинская библиотека · Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy · 2014

Triaxial transarterial embolization for lower gastrointestinal bleeding: a retrospective case series.

Shimohira Masashi, Hashizume Takuya, Ohta Kengo, Honda Junichi, Shibamoto Yuta

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Superselective transcatheter arterial embolization (TAE) is important for lower gastrointestinal (GI) bleeding. A new 1.9-Fr. no-taper microcatheter has recently become available and can be inserted into a 2.7-Fr. microcatheter. We assessed the applicability of this new triple co-axial (triaxial) system to TAE for lower GI bleeding.

MATERIAL AND

METHODS

Five patients with lower GI bleeding underwent TAE with the triaxial system. The approach was via the femoral artery with a 4-Fr. sheath in all cases. The 4-Fr. catheter and triaxial system were inserted into the artery in which extravasation had occurred. Coil embolization was performed with 0.010-inch coils. We evaluated technical success rate, clinical success rate and complications.

RESULTS

All five cases of bleeding occurred at the ascending colon, and were caused by diverticulosis in four cases, and an injury to the artery during polypectomy in one case. The 1.9-Fr. no-taper microcatheter could be inserted into the site of extravasation, the vasa recta, in all procedures and TAE was performed successfully. The disappearance of extravasation was confirmed in all cases following TAE. No patients exhibited any signs of recurrent bleeding or complication.

CONCLUSION

The triaxial system appears to be effective and useful in superselective TAE for lower GI bleeding.

Для цитирования: Shimohira Masashi, Hashizume Takuya, Ohta Kengo, Honda Junichi, Shibamoto Yuta. Triaxial transarterial embolization for lower gastrointestinal bleeding: a retrospective case series.. Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy. 2014. DOI: 10.3109/13645706.2014.951656.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.