MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/ajg.2014.126

Медицинская библиотека · The American journal of gastroenterology · 2014

A patient-blinded randomized, controlled trial comparing air insufflation, water immersion, and water exchange during minimally sedated colonoscopy.

Hsieh Yu-Hsi, Koo Malcolm, Leung Felix W

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Minimal sedation obviates patient recovery burdens, but intolerable pain limits success of cecal intubation. Painless or minimally uncomfortable insertion ensures success of cecal intubation, current patient satisfaction, and willingness to repeat future colonoscopy with minimal sedation. Water immersion (WI) and water exchange (WE), when separately compared with air insufflation (AI), significantly reduced insertion pain. To assess comparative effectiveness, we conducted a randomized controlled trial with head-to-head comparison of these three methods. We hypothesized that WE could produce the highest proportion of patients reporting painless insertion.

METHODS

This prospective patient-blinded trial (NCT01535326) enrolled minimally sedated (25 mg intramuscular meperidine) patients randomized to AI, WI, or WE (90 patients/group) to aid insertion. The previously validated primary outcome was the proportion of patients reporting painless insertion.

RESULTS

Painless insertion was reported by 30.0% (AI), 43.3% (WI), and 61.1% (WE) of patients (P<0.001). Multivariate logistic regression analysis revealed that, after adjusting for gender, body mass index, abdominal compression, position change, insertion time to cecum, and length of scope at cecum, only WE was significantly associated with painless insertion compared with AI (odds ratio (OR)=0.08, 95% confidence interval (CI)=0.03-0.24, P<0.001) or WI (OR=0.14, 95% CI=0.05-0.40, P<0.001). Adenoma detection rate (ADR) in the right (cecum and ascending) colon was 11.1% (AI), 14.4% (WI), and 26.7% (WE) (P=0.015). The limitations included single site study with unblinded colonoscopist and assistant.

CONCLUSIONS

This head-to-head comparison of AI vs. WI vs. WE confirmed that WE was superior to WI and AI, with a significantly greater proportion of patients reporting painless insertion. The significantly higher ADR in the right colon in the WE group warrants further investigations.

Для цитирования: Hsieh Yu-Hsi, Koo Malcolm, Leung Felix W. A patient-blinded randomized, controlled trial comparing air insufflation, water immersion, and water exchange during minimally sedated colonoscopy.. The American journal of gastroenterology. 2014. DOI: 10.1038/ajg.2014.126.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.