Doppler Parameters Derived from Transthoracic Echocardiography Accurately Detect Bioprosthetic Mitral Valve Dysfunction.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Spencer Ryan J, Gin Ken G, Tsang Michael Y C, Tsang Teresa S M, Nair Parvathy, Lee Pui K, Jue John
Аннотация
BACKGROUND: Detecting bioprosthetic mitral valve dysfunction on transthoracic echocardiography can be challenging because of acoustic shadowing of regurgitant jets and a wide normal range of transvalvular gradients. Several studies in mechanical mitral valves have demonstrated the utility of the transthoracically derived parameters E (peak early mitral inflow velocity), pressure half-time, and the ratio of mitral inflow velocity-time integral (VTIMV) to left ventricular outflow tract velocity-time integral (VTILVOT) in detecting significant prosthetic dysfunction. Uncertainty exists as to their applicability and appropriate cutoff levels in bioprosthetic valves. This study was designed to establish the accuracy and appropriate normal limits of routinely collected transthoracic Doppler parameters when used to assess bioprosthetic mitral valve function.
METHODS: A total of 135 clinically stable patients with bioprosthetic mitral valves who had undergone both transthoracic and transesophageal echocardiography within a 6-month period were retrospectively identified from the past 11 years of the echocardiography database. Transthoracic findings were labeled as normal (n = 81), regurgitant (n = 44), or stenotic (n = 10) according to the patient's transesophageal echocardiographic findings. Univariate and multivariate analyses were performed to identify Doppler parameters that detected dysfunction; then receiver operating characteristic curves were created to establish appropriate normal cutoff levels.
RESULTS: The VTIMV/VTILVOT ratio was the most accurate Doppler parameter at detecting valvular dysfunction, with a ratio of >2.5 providing sensitivity of 100% and specificity of 95%. E > 1.9 m/sec was slightly less accurate (93% sensitivity, 72% specificity), while a pressure half-time of >170 msec had both 100% specificity and sensitivity for detecting significant bioprosthetic mitral valve stenosis, (although it did not differentiate between regurgitant and normal).
CONCLUSIONS: This study demonstrates that Doppler parameters derived from transthoracic echocardiography can accurately detect bioprosthetic mitral valve dysfunction. These parameters, particularly a VTIMV/VTILVOT ratio of >2.5, are a sensitive way of selecting patients to undergo more invasive examination with transesophageal echocardiography.
METHODS: A total of 135 clinically stable patients with bioprosthetic mitral valves who had undergone both transthoracic and transesophageal echocardiography within a 6-month period were retrospectively identified from the past 11 years of the echocardiography database. Transthoracic findings were labeled as normal (n = 81), regurgitant (n = 44), or stenotic (n = 10) according to the patient's transesophageal echocardiographic findings. Univariate and multivariate analyses were performed to identify Doppler parameters that detected dysfunction; then receiver operating characteristic curves were created to establish appropriate normal cutoff levels.
RESULTS: The VTIMV/VTILVOT ratio was the most accurate Doppler parameter at detecting valvular dysfunction, with a ratio of >2.5 providing sensitivity of 100% and specificity of 95%. E > 1.9 m/sec was slightly less accurate (93% sensitivity, 72% specificity), while a pressure half-time of >170 msec had both 100% specificity and sensitivity for detecting significant bioprosthetic mitral valve stenosis, (although it did not differentiate between regurgitant and normal).
CONCLUSIONS: This study demonstrates that Doppler parameters derived from transthoracic echocardiography can accurately detect bioprosthetic mitral valve dysfunction. These parameters, particularly a VTIMV/VTILVOT ratio of >2.5, are a sensitive way of selecting patients to undergo more invasive examination with transesophageal echocardiography.