González de Buitrago Amigo Jesús, González García Ana, Díaz Fernández Paula, Fernández Llamas Mercedes, Tejado Bravo María Luz, de Nicolás Jiménez Jorge M, Ferrer Lozano Marta

Аннотация

BACKGROUND AND AIMS: Post-prandial glucose control is essential to achieve metabolic goals in patients with type 1 diabetes mellitus (T1DM). The new «faster aspart» insulin has a pharmacological profile noted for its faster absorption and onset of action, and increased early availability, resulting in improved blood glucose control after meals. The main objective of the study was to analyse the efficacy of «faster aspart» vs. «insulin aspart» in children and adolescents with DM1 on sensor-augmented pump treatment.

PATIENTS AND METHODS: Multicentre, longitudinal and prospective analytical trial evaluating the use of faster aspart insulin for three months in children with T1DM with MiniMed640G® sensor-augmented pumps previously treated with aspart insulin. At the beginning and end of the study the following variables were analysed for subsequent comparison: mean sensor glucose, percentage of time in range, hypoglycaemia and hyperglycaemia, area under the curve (AUC) < 70 and > 180 mg/dL, mean sensor glucose pre and postprandial in main meals, daily insulin requirements, basal/bolus percentage, and HbA1c. Acute complications, adverse events and satisfaction survey were assessed.

RESULTS: The study included 31 patients with a mean of 13.49 ± 2.42 years of age and with T1DM of 7.0 ± 3.67 years of onset. The use of faster aspart was associated with lower time in hyperglycaemia > 180 mg/dL (25.8 ± 11.3 vs. 22.4 ± 9.5; p = 0.011) and > 250 mg/dL (5.2 ± 4.9 vs. 4.0 ± 3.6; p = 0.04), lower AUC > 180 mg/dL (10.8 ± 6.5 vs. 9.3 ± 6.1; p = 0.03), and increased time in range (71.4 ± 10.0 vs. 74.3 ± 9.2; p = 0.03). No significant changes in hypoglycaemia, HbA1c, insulin requirements, and basal/bolus percentages were detected. Faster aspart was safe and well-evaluated by patients and caregivers.

CONCLUSIONS: Faster aspart achieves better glycaemic control by increasing glucose time in range in children and adolescents with T1DM on treatment with sensor-augmented pumps.