m+Medelevator.RU
← Поиск публикаций
Clinical physiology and functional imaging · 2015

Semi-quantitative myocardial perfusion measured by computed tomography in patients with refractory angina: a head-to-head comparison with quantitative rubidium-82 positron emission tomography as reference.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Qayyum Abbas Ali, Kühl Jørgen Tobias, Kjaer Andreas, Hasbak Philip, Kofoed Klaus Fuglsang, Kastrup Jens

Аннотация

INTRODUCTION: Computed tomography (CT) is a novel method for assessment of myocardial perfusion and has not yet been compared to rubidium-82 positron emission tomography (PET). We aimed to compare CT measured semi-quantitative myocardial perfusion with absolute quantified myocardial perfusion using PET and to detect stenotic territories in patients with severe coronary artery disease.

MATERIALS AND METHODS: Eighteen patients with stenosis narrowing coronary arteries ≥70% demonstrated on invasive coronary angiography underwent rest and adenosine stress imaging obtained by 320-multidetector CT scanner and CT/PET 64-slice scanner. CT measured myocardial attenuation density (AD) and perfusion index (PI) were correlated to absolute PET myocardial perfusion values.

RESULTS: Rest AD, rest and stress PI did not correlate to PET findings (r = 0·412, P = 0·113; r = 0·300, P = 0·259; and r = 0·508, P = 0·064, respectively). However, there was a significant correlation between stress AD and stress PET values (r = 0·670, P = 0·009) and between stress and rest differences for AD and PI with PET differences (r = 0·620, P = 0·006; and r = 0·639, P = 0·004, respectively). Furthermore, significant differences were observed between remote and stenotic territories for rest and stress AD (48 ± 14HU and 37 ± 16HU, P = 0·002; 76 ± 19HU and 58 ± 13HU, P<0·001, respectively), PI (9·6 ± 2·9 and 7·5 ± 3·1, P = 0·002; 21·6 ± 4·1 and 16·9 ± 3·9, P<0·001, respectively) and PET (0·96 ± 0·37 ml g-1  min-1 and 0·86 ± 0·26 ml g-1  min-1 , P = 0·036; 2·07 ± 0·76 ml g-1  min-1 and 1·61 ± 0·76 ml g-1  min-1 , P = 0·006, respectively).

CONCLUSIONS: Semi-quantitative CT parameters may be useful in the detection of myocardium subtended by stenotic coronary arteries.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049