iMap-Intravascular Ultrasound Radiofrequency Signal Analysis Reflects Plaque Components of Optical Coherence Tomography-Derived Thin-Cap Fibroatheroma.
Аннотация
BACKGROUND
The ability of iMap-intravascular ultrasound (IVUS) tissue characterization to detect thin-cap fibroatheroma (TCFA) identified on optical coherence tomography (OCT) has not yet been fully elucidated.
METHODS AND
RESULTS
We evaluated 86 coronary lesions from 73 patients with stable angina pectoris using iMap-IVUS and OCT. We defined OCT-derived TCFA (OCT-TCFA) as lipid-rich plaque with a <65-μm-thick fibrous cap. The external elastic membrane (EEM) cross-sectional area (CSA), lumen CSA, plaque plus media (P+M) CSA, plaque burden and remodeling index were measured on gray-scale IVUS. Plaque components categorized on iMap-IVUS as fibrotic, lipidic, necrotic or calcified are presented as absolute area and proportion (%) of total plaque area. OCT-TCFA (22 lesions) had significantly greater EEM CSA, P+M CSA, plaque burden and remodeling index than non-TCFA (64 lesions). Significantly larger %necrotic area, absolute lipidic and necrotic areas and smaller %fibrotic areas were found in OCT-TCFA than in non-TCFA. On multivariate analysis, absolute necrotic area was an independent predictor of OCT-TCFA. The area under the ROC curve for absolute necrotic area required to identify OCT-TCFA was 0.86. The sensitivity, specificity, positive and negative predictive values of absolute necrotic area ≥7.3 mm2 for identifying OCT-TCFA were 77%, 88%, 68% and 92%, respectively.
CONCLUSIONS
Coronary lesions with greater iMap-IVUS absolute necrotic area were closely associated with OCT-TCFA.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.