The American journal of gastroenterology · 2005
Feasibility and safety of string wireless capsule endoscopy in the diagnosis of esophageal varices.
Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ramirez Francisco C, Hakim Shahina, Tharalson Erin M, Shaukat Masud S, Akins Rodney
Аннотация
OBJECTIVE: To assess the feasibility, safety, accuracy, and acceptability of "string-capsule endoscopy" in the evaluation of esophageal varices.
MATERIAL AND METHODS: Strings were attached to the wireless capsule endoscopy device to allow its controlled movement up and down the esophagus. Time of recording and discomfort associated with the procedure was documented. Patient's preference compared to conventional esophago-gastro-duodenoscopy (EGD) was recorded. An independent endoscopist blinded to EGD diagnoses assessed the diagnostic accuracy of pictures obtained.
RESULTS: Thirty patients with clinical liver cirrhosis (mean age: 54.4 yr; mean MELD score: 12.5, and mean Child-Pugh score: 6.3) were enrolled; 19 for surveillance and 11 for screening purposes. The procedure was safe (no strings were disrupted and no capsule was lost). The mean recording time was 5.8 min (2.9-8.7), the accuracy 96.7%, and discomfort was minimal. The majority (83.3%) of patients preferred string-capsule endoscopy to EGD.
CONCLUSIONS: String-capsule endoscopy was feasible, safe, accurate, highly acceptable, and preferred by cirrhotic patients undergoing screening/surveillance of esophageal varices. The technique may prove to be more cost effective than conventional EGD.
MATERIAL AND METHODS: Strings were attached to the wireless capsule endoscopy device to allow its controlled movement up and down the esophagus. Time of recording and discomfort associated with the procedure was documented. Patient's preference compared to conventional esophago-gastro-duodenoscopy (EGD) was recorded. An independent endoscopist blinded to EGD diagnoses assessed the diagnostic accuracy of pictures obtained.
RESULTS: Thirty patients with clinical liver cirrhosis (mean age: 54.4 yr; mean MELD score: 12.5, and mean Child-Pugh score: 6.3) were enrolled; 19 for surveillance and 11 for screening purposes. The procedure was safe (no strings were disrupted and no capsule was lost). The mean recording time was 5.8 min (2.9-8.7), the accuracy 96.7%, and discomfort was minimal. The majority (83.3%) of patients preferred string-capsule endoscopy to EGD.