m+Medelevator.RU
← Поиск публикаций
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2022

Valve-in-valve transcatheter aortic valve replacement or re-surgical aortic valve replacement in degenerated bioprostheses: A systematic review and meta-analysis of short and midterm results.

СтатьяМетаанализСистематический обзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bruno Francesco, Elia Edoardo, D'Ascenzo Fabrizio, Marengo Giorgio, Deharo Pierre, Kaneko Tsuyoshi, Cuisset Thomas, Fauchier Laurent, De Filippo Ovidio, Gallone Guglielmo, Andreis Alessandro, Fortuni Federico, Salizzoni Stefano, La Torre Michele, Rinaldi Mauro, De Ferrari Gaetano M, Conrotto Federico

Аннотация

INTRODUCTION: Despite limited to short and midterm outcomes, valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) has emerged as a valid alternative to re-surgical aortic valve replacement (re-SAVR) for high- and intermediate-risk patients with degenerated surgical bioprosthesis.

METHODS: All studies comparing multivariate adjustment between ViV TAVI and re-SAVR were screened. The primary end-points were all-cause and cardiovascular (CV) mortality at 30 days and at Midterm follow-up. Short-term complications were the secondary endpoints.

RESULTS: We obtained data from 11 studies, encompassing 8570 patients, 4224 undergoing ViV TAVI, and 4346 re-SAVR. Four studies included intermediate-risk patients and seven high-risk patients. 30-day all-cause and CV mortality were significantly lower in ViV (odds ratio [OR] 0.43, 95% confidence intervals [CIs] 0.29-0.64 and OR 0.44, 0.26-0.73 respectively), while after a mean follow-up of 717 (180-1825) days, there was no difference between the two groups (OR 1.04, 0.87-1.25 and OR 1.05, 0.78-1.43, respectively). The risk of stroke (OR 1.03, 0.59-1.82), MI (OR 0.70, 0.34-1.44), major vascular complications (OR 0.92, 0.50-1.67), and permanent pacemaker implantation (OR 0.67, 0.36-1.25) at 30 days did not differ, while major bleedings and new-onset atrial fibrillation were significantly lower in ViV patients (OR 0.41, 0.25-0.67 and OR 0.23, 0.12-0.42, respectively, all 95% CIs).

CONCLUSIONS: In high- and intermediate-risk patients with degenerated surgical bioprostheses, ViV TAVI is associated with reduced short-term mortality, compared with re-SAVR. Nevertheless, no differences were found in all-cause and CV mortality at midterm follow-up. PROSPERO CRD42021226488.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты