MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mrm.30258

Медицинская библиотека · Magnetic resonance in medicine · 2024

Three-dimensional radial echo-planar spectroscopic imaging for hyperpolarized 13C MRSI in vivo.

Awenius Marcel, Abeln Helen, Müller Melanie, Franke Vanessa L, Rincon Gino, Glowa Christin, Schmitt Michaela, Bangert Renate, Ludwig Dominik, Schmidt Andreas B, Kuder Tristan A, Ladd Mark E, Bachert Peter, Biegger Philipp, Korzowski Andreas

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To demonstrate the feasibility of 3D echo-planar spectroscopic imaging (EPSI) technique with rapid volumetric radial k-space sampling for hyperpolarized (HP) 13C magnetic resonance spectroscopic imaging (MRSI) in vivo.

METHODS

A radial EPSI (rEPSI) was implemented on a 3 T clinical PET/MR system. To enable volumetric coverage, the sinusoidal shaped readout gradients per k-t-spoke were rotated along the three spatial dimensions in a golden-angle like manner. A distance-weighted, density-compensated gridding reconstruction was used, also in cases with undersampling of spokes in k-space. Measurements without and with HP 13C-labeled substances were performed in phantoms and rats using a double-resonant 13C/1H volume resonator with 72 mm inner diameter.

RESULTS

Phantom measurements demonstrated the feasibility of the implemented rEPSI sequence, as well as the robustness to undersampling in k-space up to a factor of 5 without advanced reconstruction techniques. Applied to measurements with HP [1-13C]pyruvate in a tumor-bearing rat, we obtained well-resolved MRSI datasets with a large matrix size of 123 voxels covering the whole imaging FOV of (180 mm)3 within 6.3 s, enabling to observe metabolism in dynamic acquisitions.

CONCLUSION

After further optimization, the proposed rEPSI method may be useful in applications of HP 13C-tracers where unknown or varying metabolite resonances are expected, and the acquisition of dynamic, volumetric MRSI datasets with an adequate temporal resolution is a challenge.

Для цитирования: Awenius Marcel, Abeln Helen, Müller Melanie, Franke Vanessa L, Rincon Gino, Glowa Christin, Schmitt Michaela, Bangert Renate, Ludwig Dominik, Schmidt Andreas B, Kuder Tristan A, Ladd Mark E, Bachert Peter, Biegger Philipp, Korzowski Andreas. Three-dimensional radial echo-planar spectroscopic imaging for hyperpolarized 13C MRSI in vivo.. Magnetic resonance in medicine. 2024. DOI: 10.1002/mrm.30258.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.