m+Medelevator.RU
← Поиск публикаций
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2022

Intracardiac electrogram characteristics of intramural outflow tract ventricular arrhythmias.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yalin Kivanc, Aksu Tolga, Ikitimur Baris, Onder Sukriye Ebru, Soysal Ali Ugur, Ozturk Sila, Tokdil Kardelen Nafia Inan Ohtaroglu, Yalman Hakan, Mutlu Deniz, Atici Adem, Okşul Metin, Baysal Erkan, Bilge Ahmet Kaya

Аннотация

BACKGROUND: Annotation of earliest depolarization which depends on maximum dV/dt of unipolar-electrograms and unipolar QS morphology identify site of origin for ventricular premature contractions (VPC). However, identification of unipolar QS morphology has limitations due to low spatial resolution. This study aims to compare electrogram characteristics at successful ablation site in patients with outflow tract (OT) VPC.

METHODS: Local activation time (LAT), duration, and voltage data of each bipolar- and unipolar-electrogram at the successful ablation sites from the right ventricle OT (RVOT) and the left ventricle OT (LVOT) cases were analyzed.

RESULTS: Forty-four of 60 (73%) of patients were ablated from RVOT and in 16/60 (27%) required ablation from both sides. All patients had acute VPC suppression. Bipolar-electrogram-QRS onset was earlier (36.4 ± 14.5 ms vs 26.3 ± 7.4 ms, p = 0.01), duration of bipolar-electrogram was shorter (56.9 ± 18.9 ms vs 78.9 ± 21.8 ms, p = 0.002), and bi-voltage amplitude was higher (3.2 ± 2.3 mV vs 1.4 ± 1.1 mV, p = 0.07) for patients with RVOT-only ablation. Mean bipolar-unipolar-electrogram difference was 4.4 ± 4.5 ms in the RVOT group vs 12.8 ± 4.9 ms in RVOT + LVOT group (p < 0.001). Unipolar QS morphology was recorded in 3.0 ± 3.9 vs 3.6 ± 1.8 cm2 in RVOT and RVOT + LVOT group, respectively (p = 0.41). Unipolar-electrogram revealed W pattern in 3/44 of RVOT vs 5/16 of RVOT + LVOT group, respectively (p = 0.01). In 18/60 (30%) of patients, unipolar QS was not identified at successful ablation site.

CONCLUSION: QS in unipolar-electrogram was not a perfect predictor for successful ablation sites. Analysis of bipolar voltage amplitude and duration with bipolar-unipolar-electrogram time difference may identify presence of a deeper source.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты