m+Medelevator.RU
← Поиск публикаций
Kardiologia polska · 2011

Efficacy of catheter ablation in patients with an electrical storm.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Koźluk Edward, Gaj Sylwia, Kiliszek Marek, Lodziński Piotr, Piątkowska Agnieszka, Opolski Grzegorz

Аннотация

BACKGROUND: Electrical storm (ES) is a life-threatening condition requiring prompt and effective therapy. This may be achieved by the use of catheter ablation.

AIM: To assess safety and efficacy of catheter ablation in patients with ES.

METHODS: We performed 28 ablation procedures from February 2006 to May 2010 due to ES in 24 patients (21 men, 3 women, aged 62.5 ± 7.8 years). Eighteen patients had a history of myocardial infarction, 2 - dilated cardiomyopathy, 2 - hypertrophic cardiomyopathy (one also had myocardial infarction), 1 - spongiform cardiomyopathy, 1 - heart failure after aortic valve replacement and 1 - myocarditis. The mean value of ejection fraction was 27.3 ± 6.5% (15-40%). Procedures were performed using the CARTO system. Two patients after an endocardial map had also epicardial mapping performed and one of these patients underwent epicardial cryoablation. The other one underwent a radiofrequency catheter ablation.

RESULTS: During the follow-up period of 27.8 ± 15.9 months 16 (66%) patients had no ventricular tachycardia (VT)/ventricular fibrillation (VF) episodes. Sporadic VT episodes were observed in 3 patients. Recurrence of ES occurred in 3 (12%) patients and 3 (12%) patients died during the follow-up due to the progression of heart failure.

CONCLUSIONS: 1. Ablation of ventricular arrhythmias in the course of ES in patients with organic heart disease is safe and effective, and probably improves their prognosis. 2. After ablation, some patients have adequate interventions of implantable cardioverter-defibrillator due to progression of the disease. 3. The method does not prevent haemodynamic mortality.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049