Head & neck · 2019
Submandibular gland resection via the trans-hairline approach: A preclinical study of a novel flexible single-port surgical system and the surgical experiences of standard multiarm robotic surgical systems.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yang Tsung-Lin, Li Hong, Holsinger Floyd Christopher, Koh Yoon Woo
Аннотация
BACKGROUND: Cosmetic outcome after submandibular gland (SMG) surgery has greatly improved since the development of robotic surgery through a trans-hairline approach. However, the bulky sizes of robotic arms and the rigid design of camera and instruments in the current multiarm robotic systems increased the surgical difficulty.
METHODS: Clinical and preclinical studies demonstrated the surgical configuration and procedures of robotic trans-hairline SMG resection using a flexible, single-port, and multiarm systems.
RESULTS: The surgical procedures of trans-hairline approach for SMG resection could be successfully performed using the flexible single-port (SP) robotic system in the preclinical study. The unique features include an easier docking procedure, different viewing angles, the use of the third arm, and coordination of instrument positions without a bedside assistant, which are unavailable in current multiarm robotic systems.
CONCLUSIONS: This study demonstrates the feasibility and the advantages of applying the flexible, SP robotic system in SMG resection through the trans-hairline approach.
METHODS: Clinical and preclinical studies demonstrated the surgical configuration and procedures of robotic trans-hairline SMG resection using a flexible, single-port, and multiarm systems.
RESULTS: The surgical procedures of trans-hairline approach for SMG resection could be successfully performed using the flexible single-port (SP) robotic system in the preclinical study. The unique features include an easier docking procedure, different viewing angles, the use of the third arm, and coordination of instrument positions without a bedside assistant, which are unavailable in current multiarm robotic systems.