MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8191.2008.00592.x

Медицинская библиотека · Journal of cardiac surgery · 2008

Seven-year performance of the Edwards Prima Plus stentless valve with the intact non-coronary sinus technique.

Luciani Giovanni Battista, Viscardi Francesca, Cresce Giovanni Domenico, Faggian Giuseppe, Mazzucco Alessandro

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Late results after stentless aortic valve replacement (AVR) may be jeopardized by progressive aortic dilatation. To define functional outcome using the intact non-coronary sinus technique, all patients operated using the stentless Edwards Prima Plus xenograft were assessed.

METHODS

Between January 2000 and August 2007, 154 patients, aged 71 +/- 9 years, underwent stentless AVR using a technique, which replaces the non-coronary sinus and stabilizes two of three commissures. Indication was aortic valve stenosis (AS) in 103 (67%) patients: 33 (21%) had bicuspid valve and four endocarditis. Ninety-six (62%) patients were in NYHA III-IV, and 13 (8%) had LVEF <30%. Associated procedures were required in 59 (38%) patients (CABG, 34; ascending aorta, 22; others 3). Study endpoints were survival, freedom from valve-related events, clinical status, and graft function.

RESULTS

There were two hospital and two late deaths during a 48 +/- 19 months (1-92) follow-up (97 +/- 3% survival at seven years). Seven-year freedom from structural failure, nonstructural failure, and endocarditis was 99 +/- 1%, 97 +/- 3%, and 98 +/- 2%. Follow-up NYHA (96 vs ten patients in class III-IV, p = 0.001), and cardiac function (13 vs one patient with LVEF <30%, p = 0.02) were improved. Xenograft performance was satisfactory: 0-2 + aortic insufficiency (AI) in 147 (98%) patients, mean trans-prosthetic pressure gradient 8 +/- 4 (0-25 mmHg). Aortic root diameters were comparable to postoperative values (sinus of Valsalva, 36 +/- 8 vs 35 +/- 9 mm, p = ns; sinotubular junction, 32 +/- 7 vs 34 +/- 8 mm, p = ns).

CONCLUSIONS

Stentless AVR with non-coronary sinus replacement affords excellent late outcome and low rate of valve-related events, even in complex patients (bicuspid valve, LV failure, and endocarditis). Aortic root dimensions remain stable over time allowing rewarding xenograft function.

Для цитирования: Luciani Giovanni Battista, Viscardi Francesca, Cresce Giovanni Domenico, Faggian Giuseppe, Mazzucco Alessandro. Seven-year performance of the Edwards Prima Plus stentless valve with the intact non-coronary sinus technique.. Journal of cardiac surgery. 2008. DOI: 10.1111/j.1540-8191.2008.00592.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.