m+Medelevator.RU
← Поиск публикаций
Heart (British Cardiac Society) · 2007

Incidence of aortic valve regurgitation and outcome after percutaneous closure of atrial septal defects and patent foramen ovale.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Schoen S P, Boscheri A, Lange S A, Braun M U, Fuhrmann J, Kappert U, Strasser R H

Аннотация

BACKGROUND: In recent years percutaneous, transcatheter closure of atrial septal defects (ASD) or patent foramen ovale (PFO) was introduced into clinical practice.

OBJECTIVE: To investigate the functional effects on heart valves caused by an interatrial closure device.

METHODS AND RESULTS: Between 2001 and 2006, 240 consecutive patients underwent percutaneous closure of an ASD or a PFO. Heart valve functions were defined by transoesophageal echocardiography before implantation and 3, 6 and 12 months after defect closure. A successful implantation procedure was performed in 98% of patients. Sufficient closure without residual shunt was achieved in 89% of patients with ASD and in 92% of patients with PFO. An overall major complication rate of 0.8% was apparent during the observation time (mean (SD) 27 (15) months). Long-term follow-up disclosed newly developed or worsened aortic valve regurgitation (AR) in 9% of patients with ASD and in 10% of patients with PFO. A potential cause for developing AR may be overgrowth of the device by tissue, leading to changes in interatrial septal geometry and traction on the root of the non-coronary aortic cusp.

CONCLUSION: AR occurred in 9% of patients with closed ASD and in 10% of patients with closed PFO. Indication for closure should consider this potential complication despite an otherwise safe interventional procedure.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты