m+Medelevator.RU
← Поиск публикаций
JACC. Clinical electrophysiology · 2020

Remote Monitoring Alert Burden: An Analysis of Transmission in >26,000 Patients.

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

O'Shea Catherine J, Middeldorp Melissa E, Hendriks Jeroen M, Brooks Anthony G, Lau Dennis H, Emami Mehrdad, Mishima Ricardo, Thiyagarajah Anand, Feigofsky Suzanne, Gopinathannair Rakesh, Varma Niraj, Campbell Kevin, Sanders Prashanthan

Аннотация

OBJECTIVES: This study sought to determine the remote monitoring (RM) alert burden in a multicenter cohort of patients with a cardiac implantable electronic device (CIED).

BACKGROUND: RM of CIEDs allows timely recognition of patient and device events requiring intervention. Most RM involves burdensome manual workflow occurring exclusively on weekdays during office hours. Automated software may reduce such a burden, streamlining real-time alert responses.

METHODS: We retrospectively analyzed 26,713 consecutive patients with a CIED undergoing managed RM utilizing PaceMate software between November 2018 and November 2019. Alerts were analyzed according to type, acuity (red indicates urgent, and yellow indicates nonurgent) and CIED category.

RESULTS: In total, 12,473 (46.7%) patients had a permanent pacemaker (PPM), 9,208 (34.5%) had an implantable cardioverter-defibrillator (ICD), and 5,032 (18.8%) had an implantable loop recorder (ILR). Overall, 82,797 of the 205,804 RM transmissions were alerts, with the remainder being scheduled transmissions. A total of 14,638 (54.8%) patients transmitted at least 1 alert. Permanent pacemakers were responsible for 25,700 (31.0%) alerts, ICDs for 15,643 (18.9%) alerts, and ILRs for 41,454 (50.1%) alerts, with 3,935 (4.8%) red alerts and 78,862 (95.2%) yellow alerts. ICDs transmitted 2,073 (52.7%) red alerts; 5,024 (32.1%) ICD alerts were for ventricular tachyarrhythmias and antitachycardia pacing/shock delivery.

CONCLUSIONS: In an RM cohort of 26,713 patients with CIEDs, 54.8% of patients transmitted at least 1 alert during a 12-month period, totaling over 82,000 alerts. ILRs were overrepresented, and ICDs were underrepresented, in these alerts. The enormity of the number of transmissions and the growing ILR alert burden highlight the need for new management pathways for RM.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты