Gantry-needle-target alignment technique for CT-guided needle approaches to the skull base and cranio-cervical junction.

Pileggi Marco, Ventura Elisa, Di Napoli Alberto, Piantanida Renato, Muto Mario, Cardia Andrea, Cianfoni Alessandro

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: CT-guided percutaneous procedures involving the skull base and atlanto-axial cervical spine pose particular challenges due to high density of vital vascular and nervous structures and because the ideal needle trajectory often has a cranio-caudal obliquity different from the axial scan plane. We describe how the variable CT gantry tilt, combined with gantry-needle-target alignment technique, is used to obtain precise and safe needle placement in conventional and non-conventional approaches to the skull base and the atlanto-axial spine.

METHODS

We retrospectively analyzed consecutive CT-guided needle accesses to the skull base and atlanto-axial spine performed for tissue sampling through fine-needle aspirates and core biopsies, cementoplasty of neoplastic lytic lesions of atlanto-axial spine, pain management injections, and dural puncture for cerebro-spinal fluid sampling. All the accesses were performed with the gantry-needle-target alignment technique. Procedural complications were recorded.

RESULTS

Thirty-nine CT-guided procedures were analyzed. Paramaxillary approach was used in 15 cases, postero-lateral in 11, subzygomatic in 3. Nine non-conventional approach were performed: submastoid in 3 cases, suprazygomatic in 2, trans-nasal in 2, trans-mastoid in 1, and trans-auricular in 1. Two peri-procedural complications occurred: one asymptomatic and one resolved within 24 h. All the procedures were successfully completed with successful needle access to the target.

CONCLUSION

The gantry tilt and gantry-needle-target alignment technique allows to obtain double-oblique needle accesses for CT-guided procedures involving the skull base and atlanto-axial cervical spine, minimizing uncertainty of needle trajectory and obtaining safe needle placement in conventional and non-conventional approaches.

Для цитирования: Pileggi Marco, Ventura Elisa, Di Napoli Alberto, Piantanida Renato, Muto Mario, Cardia Andrea, Cianfoni Alessandro. Gantry-needle-target alignment technique for CT-guided needle approaches to the skull base and cranio-cervical junction.. Neuroradiology. 2022. DOI: 10.1007/s00234-022-03005-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.