MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aogs.13471

Медицинская библиотека · Acta obstetricia et gynecologica Scandinavica · 2018

Arterio-venous blood gas Δvalues for validation of umbilical cord blood samples at birth are not only biased by sample mix ups but also affected by clinical factors.

Mokarami Parisa, Wiberg Nana, Källén Karin, Olofsson Per

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

Traditional validation of umbilical cord blood samples with positive veno-arterial ΔpH and arterio-venous ΔpCO2 values confirms the source of samples, whereas negative Δvalues represent mix-up of samples. To investigate whether this is true, the distributions of V-A ΔpO2 and A-V Δlactate were also explored and related to clinical characteristics. In addition, different cord blood sampling techniques were evaluated.

MATERIAL AND

METHODS

Register study with cord blood acid-base and clinical data from 27 233 newborns. Clinical characteristics were related to positive, zero and negative Δvalues. Blood samplings from unclamped and double-clamped cords were compared. A two-sided P < 0.05 was considered significant.

RESULTS

ΔpH and ΔpCO2 values distributed into positive, around zero, and negative sub-populations, with significant differences in pH and clinical characteristics between sub-populations. No such sub-populations were distinguished for ΔpO2 and Δlactate. The 2.5th and 5th ΔpH percentiles were 0.013 and 0.022, respectively, and for ΔpCO2 0.30 and 0.53 kPa. Applying 5th percentile criteria resulted in 3.5% of "Проверено" cases showing a ΔpO2  ≤ 0. Puncture and sampling of the unclamped cord resulted in significantly better sample quality.

CONCLUSIONS

Unphysiological negative ΔpO2 values occurred despite correct validation with traditional criteria. Δlactate cannot be used for validation because both positive and negative values are physiological. Positive/around zero/negative ΔpH and ΔpCO2 sub-populations were associated with significant differences in pH and clinical characteristics, indicating that defective sampling and sample handling are not the sole explanations for negative Δvalues. Prompt puncture and sampling of the unclamped cord resulted in best sample quality.

Для цитирования: Mokarami Parisa, Wiberg Nana, Källén Karin, Olofsson Per. Arterio-venous blood gas Δvalues for validation of umbilical cord blood samples at birth are not only biased by sample mix ups but also affected by clinical factors.. Acta obstetricia et gynecologica Scandinavica. 2018. DOI: 10.1111/aogs.13471.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.