MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/lrb.2019.0036

Медицинская библиотека · Lymphatic research and biology · 2019

Monitoring Leg Lymphedema Over the Course of Therapy Using an Infrared System.

Lu Iris M, Weiler Michael J, Frank Nathan D, Jordi John, Dixon J Brandon

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

Background

There are many techniques of monitoring leg lymphedema during physical therapy. Taking volumetric measurements with a tape measure is among the most common clinically, and changes in volume are typically used to measure therapy efficacy. This study shows how the Kinect infrared (IR) sensor with custom algorithms can assess leg circumferences and volumes comparable with tape measurements taken by a trained therapist while exploring regional leg changes to determine uniformity of change. Methods and

Results

Leg volumes were measured in 38 lymphedema patients using the tape measure circumference method and the Kinect IR system. Changes in circumferences in various leg regions over the course of therapy were analyzed in 23 patients. The leg circumferences (R2 = 0.9522) and volumes ( R2 = 0.9847) strongly correlated between the two methods. The Bland-Altman analysis indicated a circumference percent different bias of 1.6 (6.2%), requiring a minor correction factor between the two methods. Over the course of therapy, patients with a reduction in leg volume, defined as a change >6.5% have greater reduction most distal to the body.

Conclusion

The Kinect IR system explored can be used clinically for leg volume measurements to monitor leg lymphedema patients over the course of their therapy. Implementing analysis of regional leg changes can better inform physical therapy to improve efficacy of treatment.

Для цитирования: Lu Iris M, Weiler Michael J, Frank Nathan D, Jordi John, Dixon J Brandon. Monitoring Leg Lymphedema Over the Course of Therapy Using an Infrared System.. Lymphatic research and biology. 2019. DOI: 10.1089/lrb.2019.0036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.