m+Medelevator.RU
← Поиск публикаций
Archivos de la Sociedad Espanola de Oftalmologia · 2002

[Intraocular phakic lens ZSAL-4 for high myopia correction].

Аннотация на английскомСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Villarrubia Cuadrado A, Gallardo Galera J M, Bergillos Arillo M, Pérula de Torres L, Labella Quesada F, Palacín Miranda E

Аннотация

PURPOSE: To evaluate the effectiveness, safety and predictability of the phakic intraocular lens (IOL) ZSAL-4 for correction of high myopia.

METHODS: In this retrospective study 28 IOL in 19 patientes were implanted. The following data were recorded, preoperatively, one week, one month, 3, 6 and 12 months postoperatively: spherical equivalent (SE), astigmatism, uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), endothelial cell density (CD), coefficient of variation (CV) and intraocular pressure (IOP). We performed LASIK in 3 eyes to correct a residual refractive defect.

RESULTS: The mean age was 29.7 S.D. 5.77 years and the mean following 7.62 S.D. 7.29 months. Six months postoperatively, the preoperative SE of -14.91 S.D. 2.88 was reduced to -1.29 S.D. 0.53; the BCVA varied from 0.56 S.D. 0.16 to 0.58 S.D. 0.12; the CD changed from 2670 S.D. 252 cells/mm2 to 2344 S.D. 262. The CV showed stability. The UCVA six months postoperatively was 0.39 S.D. 0.15. No eyes lost any line of BCVA; during the first month 63% of the eyes won 2 or more lines. The efficacy index was 0.83 S.D. 0.24 one month postoperatively and 0.63 S.D. 0.32 one year postoperatively; the safety index was 1.44 D.S. 0.34 and 1.30 S.D. 0.35 respectively. One IOL was explanted the second day due to pupilary blockage; 7 eyes had transient high IOP; 2 eyes developed pupilary ovalization and in 4 cases the IOL suffered some degree of rotation. One eye presented a flat retinal detachment one year postoperatively but with no other complications. The 3 eyes submitted to LASIK presented 0.8 of BCVA the third month after LASIK.

CONCLUSIONS: ZSAL-4 IOL implantation is an effective and safe procedure with an acceptable predictability which, in some cases, could be improved with LASIK.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты