[Doppler-ophthalmomanometry in patients with obstruction of the carotid arteries].

Strauss A L, Rieger H, Schoop W

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

A novel noninvasive method to determine simultaneously ophthalmic artery pressure (OAP) and flow direction based on Doppler ultrasound principles is presented: ophthalmomanometry-Doppler (OMD). Studies performed on 25 angiographically proven normal subjects with direct recording of the internal carotid artery pressure (ICP) and indirect determination of the brachial artery pressure (BAP) demonstrated that OAP values assessed by the OMD device are highly correlated with simultaneous ipsilateral intraarterial systolic ICP measurements (r = 0.95, n = 10) and with simultaneous recordings of the BAP (r = 0.88, n = 15). In 50 patients presenting angiographically occlusions and 52 patients presenting angiographically stenoses (greater than 60%) of the carotid artery the measured Doppler ophthalmic pressure index (OPI = ratio of the ophthalmic to systemic blood pressure) was lower ipsilateral to an occlusion (0.46 +/- 0.08) than ipsilateral to a stenosis (0.54 +/- 0.08; p less than 0.001) of the carotid artery. In both it was clearly diminished compared to normal values (0.68 +/- 0.04; p less than 0.001). In carotid artery occlusions, the ipsilateral OPI was 0.46 +/- 0.06 for antegrade (n = 17) and 0.46 +/- 0.09 for retrograde (n = 28) ophthalmic artery flow. In carotid artery stenoses, the ipsilateral OPI was 0.55 +/- 0.07 for antegrade (n = 41) and 0.48 +/- 0.06 for retrograde (n = 9) ophthalmic artery flow (p less than 0.01). It is concluded that in carotid occlusions presenting a longer disease history extra-intracranial collateralisation via the ophthalmic artery are as efficient as a functional circle of Willis.

Для цитирования: Strauss A L, Rieger H, Schoop W. [Doppler-ophthalmomanometry in patients with obstruction of the carotid arteries].. Medizinische Klinik (Munich, Germany : 1983). 1989.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.