Journal of interventional cardiology · 2016
Elective or Emergency Use of Mechanical Circulatory Support Devices During Transcatheter Aortic Valve Replacement.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Singh Vikas, Damluji Abdulla A, Mendirichaga Rodrigo, Alfonso Carlos E, Martinez Claudia A, Williams Donald, Heldman Alan W, de Marchena Eduardo J, O'Neill William W, Cohen Mauricio G
Аннотация
OBJECTIVE: Evaluate the use of mechanical circulatory support (MCS) devices in high-risk patients undergoing transcatheter aortic valve replacement (TAVR).
BACKGROUND: The use of MCS devices in elderly patients with multiple comorbidities undergoing TAVR is underexplored.
METHODS: All patients undergoing TAVR at a single tertiary academic center who required MCS during index procedure between 2008 and 2015 were included in a prospective database.
RESULTS: MCS was used in 9.4% (54/577) of all TAVRs (n = 52 Edwards Sapien and n = 2 CoreValves) of which 68.5% (n = 37) were used as part of a planned strategy, and 31.5% (n = 17) were used in emergency "bail-out" situations. IABP was the most commonly used device (87%) followed by Impella and ECMO (6% each). Among the MCS group, 22% required cardiopulmonary resuscitation during the procedure (n = 4 elective [11%] vs. n = 8 emergent [47%]) and 15% upgrade to a second device (Impella or CPB after IABP; n = 5 elective [14%] vs. n = 3 emergent [18%]). Median duration of support was 1-day. Device related complications were low (4%). In-hospital mortality in this extremely high-risk population was 24% (13/54) (11% [4/37] for elective cases and 53% [9/17] for emergency cases). Cardiogenic shock (50%) was the most common cause of in-hospital death. Cumulative all-cause 1-year mortality was 35% (19/54) (19% 97/370 for elective and 71% [12/17] for emergency cases).
CONCLUSION: Emergent use of MCS during TAVR in extremely high-risk population is associated with high short and long-term mortality rates. Early identification of patients at risk for hemodynamic compromise may rationalize elective utilization of MCS during TAVR.
BACKGROUND: The use of MCS devices in elderly patients with multiple comorbidities undergoing TAVR is underexplored.
METHODS: All patients undergoing TAVR at a single tertiary academic center who required MCS during index procedure between 2008 and 2015 were included in a prospective database.
RESULTS: MCS was used in 9.4% (54/577) of all TAVRs (n = 52 Edwards Sapien and n = 2 CoreValves) of which 68.5% (n = 37) were used as part of a planned strategy, and 31.5% (n = 17) were used in emergency "bail-out" situations. IABP was the most commonly used device (87%) followed by Impella and ECMO (6% each). Among the MCS group, 22% required cardiopulmonary resuscitation during the procedure (n = 4 elective [11%] vs. n = 8 emergent [47%]) and 15% upgrade to a second device (Impella or CPB after IABP; n = 5 elective [14%] vs. n = 3 emergent [18%]). Median duration of support was 1-day. Device related complications were low (4%). In-hospital mortality in this extremely high-risk population was 24% (13/54) (11% [4/37] for elective cases and 53% [9/17] for emergency cases). Cardiogenic shock (50%) was the most common cause of in-hospital death. Cumulative all-cause 1-year mortality was 35% (19/54) (19% 97/370 for elective and 71% [12/17] for emergency cases).
CONCLUSION: Emergent use of MCS during TAVR in extremely high-risk population is associated with high short and long-term mortality rates. Early identification of patients at risk for hemodynamic compromise may rationalize elective utilization of MCS during TAVR.
Предметные рубрики MeSH
AgedAged, 80 and overAortic Valve StenosisAssisted CirculationCardiopulmonary BypassElective Surgical ProceduresEmergency Medical ServicesFemaleHospital MortalityHumansMaleOutcome and Process Assessment, Health CareProspective StudiesSeverity of Illness IndexSurvival AnalysisTranscatheter Aortic Valve ReplacementUnited States