Incidence of and Factors Associated with Sinus Membrane Perforation During Maxillary Sinus Augmentation Using the Reamer Drilling Approach: A Double-Center Case Series.

Monje Alberto, Monje-Gil Florencio, Burgueño Miguel, Gonzalez-Garcia Raúl, Galindo-Moreno Pablo, Wang Hom-Lay

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

Maxillary sinus membrane perforation has been reported as the most common intraoperative complication during sinus augmentation, potentially leading to postoperative infection and consequent loss of graft or even implant failure. Numerous anatomical factors have been demonstrated to affect membrane tearing. However, careful use of proper instrumentation, such as a reamer, seems to play an important role in minimizing the incidence of these complications. Hence, the aim of the present study was to (1) investigate the reliability of reamer drilling for lateral window preparation; (2) examine the incidence of membrane perforation; and (3) study the factors that might influence membrane perforation. Results from this study showed the safety and effectiveness of using a reamer to perform lateral window approach sinus augmentation. The sinus membrane perforation rate was found to be 12.5%. A slightly higher perforation rate was noted in thinner maxillary lateral walls (< 1.25 mm). The authors concluded that reamer drilling is a safe and effective alternate technique for opening the lateral window wall when the lateral wall thickness is ≥ 1.25mm.

Для цитирования: Monje Alberto, Monje-Gil Florencio, Burgueño Miguel, Gonzalez-Garcia Raúl, Galindo-Moreno Pablo, Wang Hom-Lay. Incidence of and Factors Associated with Sinus Membrane Perforation During Maxillary Sinus Augmentation Using the Reamer Drilling Approach: A Double-Center Case Series.. The International journal of periodontics & restorative dentistry. 2016. DOI: 10.11607/prd.2525.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.