Troponin levels after ICD implantation with and without defibrillation testing and their predictive value for outcomes: Insights from the SIMPLE trial.

Vamos Mate, Healey Jeff S, Wang Jia, Duray Gabor Z, Connolly Stuart J, van Erven Lieselot, Vinolas Xavier, Neuzner Jorg, Glikson Michael, Hohnloser Stefan H

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The Shockless IMPLant Evaluation trial randomized 2500 patients receiving a first implantable cardioverter-defibrillator (ICD)/cardiac resynchronization therapy-defibrillator device to have either defibrillation testing (DT) or no DT. It demonstrated that DT did not improve shock efficacy or reduce mortality.

OBJECTIVE

This prospective substudy evaluated the effect of DT on postoperative troponin levels and their predictive value for total and arrhythmic mortality.

METHODS

Troponin levels were measured between 6 and 24 hours after ICD implantation in 2200 of 2500 patients.

RESULTS

A postoperative serum troponin level above the upper limit of normal (ULN) was more common in patients undergoing DT (n = 509 [46.4%]) than in those not subjected to DT (n = 456 [41.3%]; P = .02). After excluding patients with known preoperative troponin levels above the ULN, consistent findings were observed (42.1% vs 37.5%; P = .04). During a mean follow-up of 3.1 ± 1.0 years, the annual mortality rate was increased in patients with postoperative troponin levels above the ULN (adjusted hazard ratio [HR] 1.43; 95% confidence interval [CI] 1.15-1.76; P = .001) irrespective of DT or no DT. Likewise, patients with elevated troponin levels had a significantly higher risk of arrhythmic death (adjusted HR 1.80; 95% CI 1.23-2.63; P = .002). The rate of first appropriate ICD shock (adjusted HR 0.89; 95% CI 0.71-1.12; P = .32) or failed appropriate shock (adjusted HR 1.02; 95% CI 0.59-1.76; P = .95) was similar in patients with or without troponin elevation.

CONCLUSION

DT at the time of ICD implantation is associated with increased troponin levels, indicating subclinical myocardial injury caused by the procedure. Elevated troponin levels but not DT seem to predict clinical outcomes in ICD recipients.

Для цитирования: Vamos Mate, Healey Jeff S, Wang Jia, Duray Gabor Z, Connolly Stuart J, van Erven Lieselot, Vinolas Xavier, Neuzner Jorg, Glikson Michael, Hohnloser Stefan H. Troponin levels after ICD implantation with and without defibrillation testing and their predictive value for outcomes: Insights from the SIMPLE trial.. Heart rhythm. 2015. DOI: 10.1016/j.hrthm.2015.11.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.