m+Medelevator.RU
← Поиск публикаций
Coronary artery disease · 2017

Three-month evaluation of strut healing using a novel optical coherence tomography analytical method following bioresorbable polymer everolimus-eluting stent implantation in humans: the TIMELESS study.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Vesga Boris, Hernandez Hector, Moncada Miguel, Gasior Pawel, Higuera Sergio, Dager Antonio, Arana Camilo, Delgado Juan A, Généreux Philippe, Maehara Akiko, Granada Juan F

Аннотация

AIMS: Bioresorbable polymer drug-eluting stent technologies have been considered to have the potential to enhance vascular healing by reducing polymer exposure to the vessel wall, potentially allowing the earlier discontinuation of dual antiplatelet therapy. At present, the early vascular healing response to this type of technologies is still unclear.

PATIENTS AND METHODS: The TIMELESS study is a multicenter, prospective, single-arm study that enrolled real-world patients undergoing percutaneous coronary intervention. All patients underwent Synergy stent implantation, which consists of a platinum-chromium platform coated with an ultra-thin abluminal bioabsorbable poly-D,L-lactide-co-glycolide polymer-eluting everolimus.

RESULTS: A total of 37 patients were included in the study. The majority of the patients underwent percutaneous coronary intervention because of acute coronary syndromes. At 3 months, angiographic follow-up showed a percentage diameter of stenosis of 8.1±7.5% and an angiographic late loss of 0.03±0.24 mm. In all analyzed struts, less than 1% of struts were definitely uncovered or covered with fibrin, 12.5% (5.0-18.5%) showed evidence of partial coverage, and the remaining (∼85%) were fully covered. No stent thrombosis was observed up to 12 months of clinical follow-up.

CONCLUSION: In a real-world population, the implantation of a bioresorbable polymer drug-eluting stent resulted in almost complete strut coverage throughout the entire stent length at 3 months. The clinical implications for antiplatelet therapy and outcomes should be investigated further.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты