Ferrer Ramírez M J, Amorós Sebastiá L I, Cano Terol C, Caballero Calabuig E, Hernández Mijares A, López Martínez R
Аннотация
OBJECTIVES: To determine the accuracy of imaging techniques for localization of nodular lesions of parathyroid glands.
MATERIAL AND METHODS: Seventy one patients were prospectively enrolled and underwent surgical examination for primary hyperparathyroidism. Ultrasonography (US), 201Tl/99mTc parathyroid subtraction scintigraphy and 99mTc MIBI scintigraphy were evaluated.
RESULTS: The sensitivity and specificity for combined 201Tl/99mTc parathyroid subtraction scintigraphy and US for parathyroid adenomas were 72.27% and 89.22% respectively. The combination of 99mTc MIBI scintigraphy and US resulted in improved specificity (93.67%) and positive predictive value (80.39%). The accuracy of the localizing studies was lower for patients with hyperplasia.
CONCLUSIONS: The combination of scintigraphy and US is the best approach for localization of nodules. In most cases, the two techniques are complementary.
MATERIAL AND METHODS: Seventy one patients were prospectively enrolled and underwent surgical examination for primary hyperparathyroidism. Ultrasonography (US), 201Tl/99mTc parathyroid subtraction scintigraphy and 99mTc MIBI scintigraphy were evaluated.
RESULTS: The sensitivity and specificity for combined 201Tl/99mTc parathyroid subtraction scintigraphy and US for parathyroid adenomas were 72.27% and 89.22% respectively. The combination of 99mTc MIBI scintigraphy and US resulted in improved specificity (93.67%) and positive predictive value (80.39%). The accuracy of the localizing studies was lower for patients with hyperplasia.
CONCLUSIONS: The combination of scintigraphy and US is the best approach for localization of nodules. In most cases, the two techniques are complementary.