MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1213/ane.0000000000007315

Медицинская библиотека · Anesthesia and analgesia · 2024

Defining Postinduction Hemodynamic Instability With an Automated Classification Model.

Kho Eline, Immink Rogier V, van der Ster Bjorn J P, van der Ven Ward H, Schenk Jimmy, Hollmann Markus W, Tol Johan T M, Terwindt Lotte E, Vlaar Alexander P J, Veelo Denise P

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Postinduction hypotension (PIH) may be associated with increased morbidity and mortality. In earlier studies, the definition of PIH is solely based on different absolute or relative thresholds. However, the time-course (eg, how fast blood pressure drops during induction) is rarely incorporated, whereas it might represent the hemodynamic instability of a patient. We propose a comprehensive model to distinguish hemodynamically unstable from stable patients by combining blood pressure thresholds with the magnitude and speed of decline.

METHODS

This prospective study included 375 adult elective noncardiac surgery patients. Noninvasive blood pressure was continuously measured between 5 minutes before up to 15 minutes after the first induction agent had been administered. An expert panel rated whether the patient experienced clinically relevant hemodynamic instability or not. Interrater correlation coefficient and intraclass correlation were computed to check for consistency between experts. Next, an automated classification model for clinically relevant hemodynamic instability was developed using mean, maximum, minimum systolic, mean, diastolic arterial blood pressure (SAP, MAP, and DAP, respectively) and their corresponding time course of decline. The model was trained and tested based on the hemodynamic instability labels provided by the experts.

RESULTS

In total 78 patients were classified as having experienced hemodynamic instability and 279 as not. The hemodynamically unstable patients were significantly older (7 years, 95% confidence interval (CI), 4-11, P < .001), with a higher prevalence of chronic obstructive pulmonary disease (COPD) (3% higher, 95% CI, 1-8, P = .036). Before induction, hemodynamically unstable patients had a higher SAP (median (first-third quartile): 161 (145-175) mm Hg vs 150 (134-166) mm Hg, P < .001) compared to hemodynamic stable patients. Interrater agreement between experts was 0.92 (95% CI, 0.89-0.94). The random forest classifier model showed excellent performance with an area under the receiver operating curve (AUROC) of 0.96, a sensitivity of 0.84, and specificity of 0.94.

CONCLUSIONS

Based on the high sensitivity and specificity, the developed model is able to differentiate between clinically relevant hemodynamic instability and hemodynamic stable patients. This classification model will pave the way for future research concerning hemodynamic instability and its prevention.

Для цитирования: Kho Eline, Immink Rogier V, van der Ster Bjorn J P, van der Ven Ward H, Schenk Jimmy, Hollmann Markus W, Tol Johan T M, Terwindt Lotte E, Vlaar Alexander P J, Veelo Denise P. Defining Postinduction Hemodynamic Instability With an Automated Classification Model.. Anesthesia and analgesia. 2024. DOI: 10.1213/ane.0000000000007315.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.