Smart scanning for two: [18F]FDG dose optimization for pregnant patients using LAFOV PET/CT technology.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Deurloo Ilja S, Steemers-de Boer Milou M, van Snick Johannes H, Koopmans Klaas Pieter, Slart Riemer H J A, Noordzij Walter, Brouwers Adrienne H, Stormezand Gilles N, Velleman Ton, Aarntzen Erik H J G, de Wit-van der Veen Berlinda J, Vogel Wouter V, Jansen Sanne M, Braat Arthur J A T, Glaudemans Andor W J M, Ivashchenko Oleksandra V

Аннотация

PURPOSE: This study aimed to evaluate the image quality-dose trade-off in pregnant patients imaged with long-axial field-of-view [18F]FDG PET/CT and to identify the most predictive body composition metric for image quality to develop a pregnancy-tailored dosage model.

METHODS: Patients imaged with [18F]FDG PET/CT according to local pregnancy protocols were included in this study. Using raw PET data, images of various degrees of image quality were reconstructed. Acceptable image quality was identified using signal-to-noise ratio (SNR) in the liver and Likert scores. The minimum required scan statistics was modelled based on SNR and patient body composition. F-tests were used to find the best-fitting model parameter out of weight, weight-to-height-ratio, body-mass-index, and body surface area (BSA). Foetal dose was estimated with PET conversion factors and size-specific CT dose index values.

RESULTS: Eleven patients were included in image quality analysis and dosage model optimization. SNR strongly correlated with Likert scores (R² = 0.80), with 10.72 SNR indicating acceptable image quality. BSA best predicted image quality (R² = 0.85), outperforming weight (R² = 0.78), weight-to-height ratio (R² = 0.63), and body mass index (R² = 0.38). The proposed dosage model reduces activity by 41-96% compared to current local pregnancy and adult protocols, resulting in estimated foetal radiation doses of 0.066 mGy (PET) and 0.31 mGy (CT).

CONCLUSION: BSA accurately predicted [18F]FDG PET/CT image quality in pregnant patients. The proposed dosage regimen allows significant dose reduction and can be used as a foundation for the development of pregnancy dosage protocols.