KIF6 Trp719Arg Genetic Variant Increases Risk for Thoracic Aortic Dissection.

Velasco Juan J, Li Yupeng, Ziganshin Bulat A, Zafar Mohammad A, Rizzo John A, Ma Deqiong, Zang Hui, Kalyanasundaram Asanish, Elefteriades John A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

KIF6 (kinesin family member 6), a protein coded by the KIF6 gene, serves an important intracellular function to transport organelles along microtubules. In a pilot study, we found that a common KIF6 Trp719Arg variant increased the propensity of thoracic aortic aneurysms (TAA) to suffer dissection (AD). The present study aims for a definite investigation of the predictive ability of KIF6 719Arg vis à vis AD. Confirmatory findings would enhance natural history prediction in TAA.

METHODS

1108 subjects (899 aneurysm and 209 dissection patients) had KIF6 719Arg variant status determined.

RESULTS

The 719Arg variant in the KIF6 gene correlated strongly with occurrence of AD. Specifically, KIF6 719Arg positivity (homozygous or heterozygous) was substantially more common in dissectors (69.8%) than non-dissectors (58.5%) (p = 0.003). Odds ratios (OR) for suffering aortic dissection ranged from 1.77 to 1.94 for Arg carriers in various dissection categories. These high OR associations were noted for both ascending and descending aneurysms and for homozygous and heterozygous Arg variant patients. The rate of aortic dissection over time was significantly higher for carriers of the Arg allele (p = 0.004). Additionally, Arg allele carriers were more likely to reach the combined endpoint of dissection or death (p = 0.03).

CONCLUSIONS

We demonstrate the marked adverse impact of the 719Arg variant of the KIF6 gene on the likelihood that a TAA patient will suffer aortic dissection. Clinical assessment of the variant status of this molecularly important gene may provide a valuable "non-size" criterion to enhance surgical decision making above and beyond the currently used metric of aortic size (diameter).

Для цитирования: Velasco Juan J, Li Yupeng, Ziganshin Bulat A, Zafar Mohammad A, Rizzo John A, Ma Deqiong, Zang Hui, Kalyanasundaram Asanish, Elefteriades John A. KIF6 Trp719Arg Genetic Variant Increases Risk for Thoracic Aortic Dissection.. Genes. 2023. DOI: 10.3390/genes14020252.