MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2017.01.088

Медицинская библиотека · International journal of cardiology · 2017

Impact of closure devices on vascular complication and mortality rates in TAVI procedures.

Dimitriadis Zisis, Scholtz Werner, Börgermann Jochen, Wiemer Marcus, Piper Cornelia, Vlachojannis Mario, Gummert Jan, Horstkotte Dieter, Ensminger Stephan, Faber Lothar, Scholtz Smita

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Currently two closure devices are available for the vascular access in TAVI procedures. Their impact on vascular complications and mid-term mortality is yet unknown.

METHODS

Between 2009 and 2014, 398 patients underwent TAVI TF procedures in which two different closure devices were used, Prostar® XL (n=215) and Perclose-Proglide® (n=183). In the cases with Prostar we used one device and in cases with Perclose-Proglide, two devices. The two groups were compared with respect to the criteria of the Valve Academic Research Consortium (VARC) II. The mean follow-up period was 679.7±481.8 (727) days.

RESULTS

There were no significant differences in the baseline characteristics of both patient groups. In the Prostar® group, complications were more frequent (26.6% vs. 12.6%, p=0.005); in detail, these were bleeding (14.9% vs. 7.1%, [p]=0.02), suture rupture (4.7% vs. 1.3%, p=0.04), and pseudoaneurysms (10.2% vs. 1.2%, p<0.001). Multivariate regression analysis revealed two predictors for vascular complications: female sex (OR 2.3; 95% CI 1.3-3.8, p=0.002) and closure devices (OR 0.5; 95% CI 0.3-0.8, p=0.007) in favour of Proglide®. There was no significant difference in 30-day mortality (Prostar: 5.6±1.6% vs. Proglide: 4.9±1.6%). However, Kaplan-Meier survival analysis showed a significantly higher survival rate over the entire follow-up period for the Proglide® group (p=0.03).

CONCLUSION

Vascular complications occurred more often in the Prostar® group. Although 30-day mortality showed no significant difference between the groups, the mortality over complete follow-up was significantly lower in the Proglide® group.

Для цитирования: Dimitriadis Zisis, Scholtz Werner, Börgermann Jochen, Wiemer Marcus, Piper Cornelia, Vlachojannis Mario, Gummert Jan, Horstkotte Dieter, Ensminger Stephan, Faber Lothar, Scholtz Smita. Impact of closure devices on vascular complication and mortality rates in TAVI procedures.. International journal of cardiology. 2017. DOI: 10.1016/j.ijcard.2017.01.088.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.