MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2016.11.032

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2016

Characterizing saccular aortic arch aneurysms from the geometry-flow dynamics relationship.

Natsume Kayoko, Shiiya Norihiko, Takehara Yasuo, Sugiyama Masataka, Satoh Hiroshi, Yamashita Katsushi, Washiyama Naoki

СтатьяVideo-Audio MediaПеревод пока не подготовлен

Аннотация

OBJECTIVE

Low wall shear stress (WSS) has been reported to be associated with accelerated atherosclerosis, aneurysm growth, or rupture. We evaluated the geometry of aortic arch aneurysms and their relationship with WSS by using the 4-dimensional flow magnetic resonance imaging to better characterize the saccular aneurysms.

METHODS

We analyzed the geometry in 100 patients using multiplanar reconstruction of computed tomography. We evaluated WSS and vortex flow using 4-dimensional flow magnetic resonance imaging in 16 of them, which were compared with 8 age-matched control subjects and eight healthy young volunteers.

RESULTS

Eighty-two patients had a saccular aneurysm, and 18 had a fusiform aneurysm. External diameter/aneurysm length ratio and sac depth/neck width ratio of the fusiform aneurysms were constant at 0.76 ± 0.18 and 0.23 ± 0.09, whereas those of saccular aneurysms, especially those involving the outer curvature, were higher and more variable. Vortex flow was always present in the aneurysms, resulting in low WSS. When the sac depth/neck width ratio was less than 0.8, peak WSS correlated inversely with luminal diameter even in the saccular aneurysms. When this ratio exceeded 0.8, which was the case only with the saccular aneurysms, such correlation no longer existed and WSS was invariably low.

CONCLUSIONS

Fusiform aneurysms elongate as they dilate, and WSS is lower as the diameter is larger. Saccular aneurysms dilate without proportionate elongation, and they, especially those occupying the inner curvature, have higher and variable sac depth/neck width ratio. When this ratio exceeds 0.8, WSS is low regardless of diameter, which may explain their malignant clinical behavior.

Для цитирования: Natsume Kayoko, Shiiya Norihiko, Takehara Yasuo, Sugiyama Masataka, Satoh Hiroshi, Yamashita Katsushi, Washiyama Naoki. Characterizing saccular aortic arch aneurysms from the geometry-flow dynamics relationship.. The Journal of thoracic and cardiovascular surgery. 2016. DOI: 10.1016/j.jtcvs.2016.11.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.