MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3171/foc.2009.26.2.e13

Медицинская библиотека · Neurosurgical focus · 2009

High-resolution ultrasonography in evaluating peripheral nerve entrapment and trauma.

Koenig Ralph W, Pedro Maria T, Heinen Christian P G, Schmidt Thomas, Richter Hans-Peter, Antoniadis Gregor, Kretschmer Thomas

Клинический случайСтатьяОбзорПеревод пока не подготовлен

Аннотация

High-resolution ultrasonography is a noninvasive, readily applicable imaging modality, capable of depicting real-time static and dynamic morphological information concerning the peripheral nerves and their surrounding tissues. Continuous progress in ultrasonographic technology results in highly improved spatial and contrast resolution. Therefore, nerve imaging is possible to a fascicular level, and most peripheral nerves can now be depicted along their entire anatomical course. An increasing number of publications have evaluated the role of high-resolution ultrasonography in peripheral nerve diseases, especially in peripheral nerve entrapment. Ultrasonography has been shown to be a precious complementary tool for assessing peripheral nerve lesions with respect to their exact location, course, continuity, and extent in traumatic nerve lesions, and for assessing nerve entrapment and tumors. In this article, the authors discuss the basic technical considerations for using ultrasonography in peripheral nerve assessment, and some of the clinical applications are illustrated.

Для цитирования: Koenig Ralph W, Pedro Maria T, Heinen Christian P G, Schmidt Thomas, Richter Hans-Peter, Antoniadis Gregor, Kretschmer Thomas. High-resolution ultrasonography in evaluating peripheral nerve entrapment and trauma.. Neurosurgical focus. 2009. DOI: 10.3171/foc.2009.26.2.e13.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.