BACKGROUND

There are few in vivo and ex vivo models for training in endoscopic sphincterotomy (ES) and endoscopic papillectomy (EP).

OBJECTIVE

We describe in vivo and ex vivo training pig models that use a simulated papilla for hands-on teaching of ES and EP.

DESIGN

Animal experiment.

SETTING

A referral center.

MATERIALS AND INTERVENTIONS: Hyaluronate solution (0.4%) was injected submucosally using a 25-gauge sclerotherapy needle to create a submucosal bleb by using porcine in vivo stomach, ex vivo stomach, and ex vivo rectum. ES and EP were then performed by using a pull-type sphincterotome and snare, respectively.

MAIN OUTCOME MEASUREMENT: The feasibility of creating a simulated papilla for ES and EP procedures was tested by experienced and nonexperienced ERCP endoscopists.

RESULTS

Creation of a hemispheroidal bulge was successful in 13 of 17 (76%) areas within an in vivo stomach, 13 of 16 (81%) areas of an ex vivo stomach, and 16 of 16 (100%) areas in an ex vivo rectum. In the in vivo stomach model, ES was successfully and realistically performed on the anterior wall of the stomach rather than in other walls. In the ex vivo stomach model, endoscopists experienced in ERCP and trainees performed ES without difficulty, whereas it was difficult or impossible for nonexperienced trainees to perform ES. In the ex vivo rectum model, all 3 endoscopists were able to complete not only ES but also EP.

LIMITATIONS: Pilot study.

CONCLUSIONS

Although further studies are necessary to evaluate the reproducibility and cost-effectiveness, this novel pig model appears useful for ES and EP training.

Для цитирования: Itoi Takao, Gotoda Takuji, Baron Todd H, Sofuni Atsushi, Itokawa Fumihide, Tsuji Shujiro, Tsuchiya Takayoshi, Tanaka Rena, Tonozuka Ryosuke, Honjo Mitsuyoshi, Ryozawa Shomei, Kawai Takashi, Moriyasu Fuminori, Isayama Hiroyuki. Creation of simulated papillae for endoscopic sphincterotomy and papillectomy training by using in vivo and ex vivo pig model (with videos).. Gastrointestinal endoscopy. 2013. DOI: 10.1016/j.gie.2012.12.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.