MedElevator Войти в исследования
← Поиск публикаций

DOI 10.25259/jcis_158_2021

Медицинская библиотека · Journal of clinical imaging science · 2021

Abnormal Findings on "T1WI or DWI or MRCP:" An Effective Boolean Interpretation Model in Discriminating Small Pancreatic Ductal Adenocarcinoma from Control Group.

Ren Hainan, Mori Naoko, Hirasawa Minami, Hamada Shin, Mugikura Shunji, Masamune Atsushi, Takase Kei

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The objectives of the study was to evaluate the diagnostic performance of findings on T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), and magnetic resonance cholangiopancreatography (MRCP) separately and to identify an optimal Boolean interpretation model for discriminating patients with small pancreatic ductal adenocarcinoma (PDAC) from control groups in clinical practice.

MATERIAL AND

METHODS

We retrospectively enrolled 30 patients with surgery confirmed small PDAC (≤20 mm) and 302 patients without pancreatic abnormality between April 2008 and February 2020. The presence of masses was evaluated by T1WI, T2WI, and DWI. Abnormality of the main pancreatic duct (MPD) was evaluated by T2WI and MRCP. Multivariate logistic regression analysis was performed to select significant sequences for discriminating the small PDAC and control groups. Boolean operators "OR" or "AND" were used to construct sequence combinations. Diagnostic performances of these sequences and combinations were evaluated by X 2 tests.

RESULTS

The sensitivity of T2WI was lowest (20%) for detecting masses. For evaluating MPD abnormality, sensitivity was higher for MRCP than for T2WI (86.7% vs. 53.3%). Multivariate logistic regression analysis showed that T1WI and DWI for detecting the presence of masses and MRCP for evaluating MPD abnormality were significantly associated with differentiation between the two groups (P = 0.0002, P = 0.0484, and P < 0.0001, respectively). Seven combinations were constructed with T1WI, DWI, and MRCP. The combination of findings on "T1WI or DWI or MRCP" achieved the highest sensitivity of 96.7% and negative predictive value of 99.6%.

CONCLUSION

The combination of findings on "T1WI or DWI or MRCP" might be an optimal interpretation model for discriminating small PDAC from control groups in clinical practice.

Для цитирования: Ren Hainan, Mori Naoko, Hirasawa Minami, Hamada Shin, Mugikura Shunji, Masamune Atsushi, Takase Kei. Abnormal Findings on "T1WI or DWI or MRCP:" An Effective Boolean Interpretation Model in Discriminating Small Pancreatic Ductal Adenocarcinoma from Control Group.. Journal of clinical imaging science. 2021. DOI: 10.25259/jcis_158_2021.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.