Journal of magnetic resonance imaging : JMRI · 2008
3D nongadolinium-enhanced ECG-gated MRA of the distal lower extremities: preliminary clinical experience.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lim Ruth P, Hecht Elizabeth M, Xu Jian, Babb James S, Oesingmann Niels, Wong Samson, Muhs Bart E, Gagne Paul, Lee Vivian S
Аннотация
PURPOSE: To report our initial experience implementing a noncontrast-enhanced electrocardiograph (ECG) gated fast spin echo magnetic resonance angiography (MRA) technique for assessment of the calf arteries.
MATERIALS AND METHODS: Noncontrast MRA images of 36 clinical patients examined over a 6-month period were evaluated by two radiologists for length and degree of stenosis of arterial segments. Diagnostic confidence in the technique was also recorded. The reference standard was a consensus reading by both radiologists using the noncontrast technique combined with two gadolinium-enhanced techniques: bolus-chase and time-resolved imaging.
RESULTS: For stenosis evaluation the noncontrast technique demonstrated accuracy 79.4% (1083/1364), sensitivity 85.4% (437/512), and specificity 75.8% (646/852). The sequence demonstrated high negative predictive value (92.3%, 646/700). The technique had serious artifacts leading to poor diagnostic confidence in 17 patients (47.2%). These included motion (n = 7) and artifacts specific to the sequence, including inaccurate trigger delays (n = 5), linear artifact (n = 7), and vessel blurring (n = 5). When only patients in whom there was satisfactory diagnostic confidence were considered, accuracy, sensitivity, and negative predictive value were 92.2% (661/717), 92.4% (158/171), and 97.5% (503/516), respectively.
CONCLUSION: Our results indicate that when technically successful, noncontrast-enhanced MRA using ECG-gated fast spin echo can provide accurate imaging of the calf and pedal arteries. However, further development and optimization are needed to improve the robustness of the technique.
MATERIALS AND METHODS: Noncontrast MRA images of 36 clinical patients examined over a 6-month period were evaluated by two radiologists for length and degree of stenosis of arterial segments. Diagnostic confidence in the technique was also recorded. The reference standard was a consensus reading by both radiologists using the noncontrast technique combined with two gadolinium-enhanced techniques: bolus-chase and time-resolved imaging.
RESULTS: For stenosis evaluation the noncontrast technique demonstrated accuracy 79.4% (1083/1364), sensitivity 85.4% (437/512), and specificity 75.8% (646/852). The sequence demonstrated high negative predictive value (92.3%, 646/700). The technique had serious artifacts leading to poor diagnostic confidence in 17 patients (47.2%). These included motion (n = 7) and artifacts specific to the sequence, including inaccurate trigger delays (n = 5), linear artifact (n = 7), and vessel blurring (n = 5). When only patients in whom there was satisfactory diagnostic confidence were considered, accuracy, sensitivity, and negative predictive value were 92.2% (661/717), 92.4% (158/171), and 97.5% (503/516), respectively.
CONCLUSION: Our results indicate that when technically successful, noncontrast-enhanced MRA using ECG-gated fast spin echo can provide accurate imaging of the calf and pedal arteries. However, further development and optimization are needed to improve the robustness of the technique.