Anti-inflammatory effect of abciximab-coated stent in a porcine coronary restenosis model.

Hong Young Joon, Jeong Myung Ho, Lee Sang Rok, Hong Seo Na, Kim Kye Hun, Park Hyung Wook, Kim Ju Han, Kim Weon, Ahn Youngkeun, Cho Jeong Gwan, Park Jong Chun, Kang Jung Chaee

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The aim of this study was to examine the anti-inflammatory effect of abciximab-coated stent in a porcine coronary overstretch restenosis model. Ten abciximab-coated stents, ten sirolimus-eluting stents (SES), and ten paclitaxel-eluting stents (PES) were deployed with oversizing (stent/artery ratio 1.3:1) in porcine coronary arteries, and histopathologic analysis was done at 28 days after stenting. There were no significant differences in the neointima area normalized to injury score and inflammation score among the three stent groups (1.58 +/- 0.43 mm(2), 1.57 +/-0.39 mm(2) in abciximab-coated stent group vs. 1.69 +/- 0.57 mm(2), 1.72 +/- 0.49 mm(2) in the SES group vs. 1.92 +/- 0.86 mm(2), 1.79 +/- 0.87 mm(2) in the PES group, respectively). In the neointima, most inflammatory cells were lymphohistiocytes. Significant positive correlations were found between the extent of inflammatory reaction and the neointima area (r=0.567, p<0.001) and percent area stenosis (r=0.587, p<0.001). Significant correlations were found between the injury score and neointimal area (r=0.645, p<0.001), between the injury score and the inflammation score (r=0.837, p<0.001), and between the inflammation score and neointimal area (r=0.536, p=0.001). There was no significant difference in the inflammatory cell counts normalized to injury score among the three stent groups (75.5 +/- 23.1/microL in abciximabcoated stent group vs. 78.8 +/- 33.2/microL in the SES group vs. 130.3 +/- 46.9/microL in the PES group). Abciximab-coated stent showed comparable inhibition of inflammatory cell infiltration and neointimal hyperplasia with other drug-eluting stents in a porcine coronary restenosis model.

Для цитирования: Hong Young Joon, Jeong Myung Ho, Lee Sang Rok, Hong Seo Na, Kim Kye Hun, Park Hyung Wook, Kim Ju Han, Kim Weon, Ahn Youngkeun, Cho Jeong Gwan, Park Jong Chun, Kang Jung Chaee. Anti-inflammatory effect of abciximab-coated stent in a porcine coronary restenosis model.. Journal of Korean medical science. 2007. DOI: 10.3346/jkms.2007.22.5.802.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.