DOI 10.1016/j.bjan.2019.03.001
[Ultrasound assessment of gastric antrum in term pregnant women before elective cesarean section].
Аннотация
BACKGROUND AND
OBJECTIVES
Pregnant women are considered patients at risk for pulmonary aspiration of gastric contents. The study aim was to evaluate the gastric antral cross-sectional area using ultrasound.
METHOD: In this prospective study, 85 scheduled term pregnant women underwent gastric ultrasound. The outcomes were the measurement of the gastric antral cross-sectional area (main outcome), the estimated gastric volume, the incidence of pregnant women at risk for pulmonary aspiration, and the association between gastric antral cross-sectional area and clinical-demographic characteristics. Gastric antral cross-sectional area and gastric volume were compared according to body mass index <30 or ≥30.
RESULTS
The median (IIQ) for gastric antral cross-sectional area was 4 cm2 (2.8–6.3), for the estimated gastric volume it was 49.8 mL (33.7–87.2), and for the gastric volume estimated in mL.kg−1 it was 0.62 mL.kg−1 (0.39–0.95). The 95th percentile [95% confidence interval (CI)] of the gastric antral cross-sectional area and the estimated gastric volume were ≤10.3 cm2 (95% CI: 7.6–15.6) and 1.42 mL.kg−1 (95% CI: 1.20–2.64), respectively. The incidence of pregnant women at risk for pulmonary aspiration was 3.5% (CI: 3.5 (1.2–9.8)). There was a positive correlation between gastric antral cross-sectional area and weight, p < 0.001 and body mass index <0.001. Patients with a body mass index ≥30 had a gastric antral cross-sectional area and an estimated gastric volume greater than those with a body mass index <30, respectively, p < 0.01 and p < 0.02.
CONCLUSION
Measuring the gastric antral cross-sectional area of pregnant women is feasible and easy. There was positive correlation between gastric antral cross-sectional area, body weight and body mass index. The estimation of gastric volume by measuring the gastric antral cross-sectional area can identify patients at risk for pulmonary aspiration. Obese patients had a gastric antral cross-sectional area and an estimated gastric volume greater than non-obese patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.