MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40644-025-00960-3

Медицинская библиотека · Cancer imaging : the official publication of the International Cancer Imaging Society · 2026

Radiomic features of CECT and SUVmax of dual-tracer PET/CT reveal PD-L1 spatial heterogeneity in PDAC.

Swain Sashikanta, Mohakud Sudipta, Mandal Srijani, Padhi Siba Narayan, Pattnaik Bramhadatta, Gupta Sunita, Rout Sipra, Mishra Pravash Ranjan, Agrawal Kanhaiyalal

СтатьяПеревод пока не подготовлен

Аннотация

Pancreatic ductal adenocarcinoma (PDAC) is characterized by limited responsiveness to immunotherapy due to spatial heterogeneity of PD-L1 expression. Invasive biopsy-based assessments may fail to capture this heterogeneity. This study aims to evaluate non-invasive imaging biomarkers to predict the expression of PD-L1 in 52 PDAC patients using CECT and F-18 FDG PET/CT and Ga-68 FAPI-04 PET/CT imaging. Intensity histogram and Gray Level Co-occurrence Matrix (GLCM) features were extracted from CECT using IBEX software. PD-L1 expression was validated by immunohistochemistry, RT-PCR, and Western blotting. Correlation between PD-L1 expression, SUVmax of F-18 FDG, and FAPI-04 PET/CT and radiomic CECT features were assessed. PDAC tissues demonstrated multimodal intensity histograms with lower histogram peak height correlated with high PD-L1 expression. A moderate positive correlation was observed between PD-L1 expression and FDG uptake (R2 = 0.36) and a weaker correlation with FAPI uptake (R2 = 0.19). This Multi-parametric imaging can enhance immunohistochemistry, aiding in patient stratification for immunotherapy and overcoming the limitations of single-site biopsies.

Для цитирования: Swain Sashikanta, Mohakud Sudipta, Mandal Srijani, Padhi Siba Narayan, Pattnaik Bramhadatta, Gupta Sunita, Rout Sipra, Mishra Pravash Ranjan, Agrawal Kanhaiyalal. Radiomic features of CECT and SUVmax of dual-tracer PET/CT reveal PD-L1 spatial heterogeneity in PDAC.. Cancer imaging : the official publication of the International Cancer Imaging Society. 2026. DOI: 10.1186/s40644-025-00960-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.