The effect of bracket slot size on the effectiveness of orthodontic treatment: A systematic review.
Аннотация
OBJECTIVES
To assess, by means of a systematic review, the scientific evidence of the influence of 0.018-inch or 0.022-inch bracket slots on treatment time, efficiency of space closure, efficiency of alignment, quality of orthodontic finishing, level of discomfort, and level of root resorption.
MATERIALS AND
METHODS
The PubMed, Bireme, Medline, Scopus, Web of Science, Open Grey, and Google Scholar databases were searched, with no date and language restrictions, for randomized clinical trials and controlled clinical trials, using controlled terms related to bracket slots. After the selection and removal of duplicate articles, the risk of bias was assessed, and the data from the included studies were extracted by two independent researchers.
RESULTS
The search yielded 2640 studies. After applying the eligibility criteria, eight articles were fully read and four studies were selected for the qualitative systematic review. No randomized clinical trials assessed the duration of treatment in patients treated with 0.018-inch and 0.022-inch bracket slots. Due to heterogeneity of the data available, a meta-analysis could not be conducted.
CONCLUSIONS
While most studies indicated a shorter duration of treatment in patients with 0.018-inch bracket slots, no available data confirmed the higher efficiency of one system over the other. The biases in the studies did not allow for a reliable conclusion; therefore, new studies with a better methodologic design are needed.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.